Technical Guide
Table Of Contents
- Dell EMC PowerEdge T150 Technical Guide
- Contents
- System overview
- System features and generational comparison
- Chassis views and features
- Processor
- Memory subsystem
- Storage
- PCIe subsystem
- Power, thermal, and acoustics
- Supported operating systems
- Dell EMC OpenManage systems management
- Dell Technologies Services
- Dell EMC ProDeploy Enterprise Suite
- Dell EMC Remote Consulting Services
- Dell EMC Data Migration Service
- Dell EMC ProSupport Enterprise Suite
- Dell EMC ProSupport Plus for Enterprise
- Dell EMC ProSupport for Enterprise
- Dell EMC ProSupport One for Data Center
- ProSupport for HPC
- Support Technologies
- Dell Technologies Education Services
- Dell Technologies Consulting Services
- Dell EMC Managed Services
- Appendix A: Additional specifications
- Appendix B. Standards compliance
- Appendix C Additional resources
Chassis weight
Table 21. PowerEdge T150 system weight
System configuration Maximum weight (with all drives/SSDs)
4 x 3.5-inch system 11.68 kg (25.74 lbs.)
USB ports specifications
Table 22. PowerEdge T150 USB ports specifications
Front Rear Internal
USB port type No. of ports USB port type No. of ports USB port type No. of ports
USB 3.0 -
compliant port
One
USB 2.0 -
compliant port
Five
Internal USB 3.0 -
compliant port
One
iDRAC Direct port
(Micro-AB USB
2.0-compliant
port)
One
USB 3.0 -
compliant port
One
NOTE: The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port.
Power Supply Units
Energy Smart power supplies have intelligent features, such as the ability to dynamically optimize efficiency while maintaining
availability and redundancy. Also featured are enhanced power-consumption reduction technologies, such as high-efficiency
power conversion and advanced thermal-management techniques, and embedded power-management features, including high-
accuracy power monitoring. The table below shows the power supply unit options that are available for the T150.
Table 23. PowerEdge T150 PSU specifications
PSU Class Heat
dissipation
(maximum)
Frequency Voltage AC DC Current
High line
200–240
V
Low line
100–120 V
300 W AC Bronze 1024 BTU/
hr
50/60 Hz 100–240 V
AC,
autoranging
300 W 300 W NA 4.6 A
400 W AC
(available
only from
Dec’21)
Platinum 1365 BTU/
hr
50/60 Hz 100–240 V
AC,
autoranging
400 W 400 W NA 5.4 A
NOTE: Heat dissipation is calculated using the PSU wattage rating.
NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
Appendix A: Additional specifications 41