Reference Guide
Command History
This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.9(0.0) Introduced on the C9010.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series ExaScale.
7.5.1.0 Introduced on the C-Series.
7.6.1.0 Introduced on the E-Series
Usage Information
If you disable auto failover, enter the redundancy auto-failover-limit
(without any parameters) to set auto failover to the default parameters (Count 3,
Period 60 minutes). To view the redundancy status, use the show redundancy
command.
When you change one or both of the optional parameters, Dell Networking OS
checks that the interval between auto failovers is more than five (5) minutes. If the
interval is less, Dell Networking OS returns a configuration error message.
redundancy disable-auto-reboot
Prevent the system from auto-rebooting the failed module.
C9000 Series
Syntax
redundancy disable-auto-reboot {linecard [slot—id | all] | pe
pe-id stack unit unit-number | all | rpm}
Parameters
lincard slot-id / all Enter the keyword linecard with the slot-id to specify a
linecard, or all to select all linecards. Linecard ID. Range is
from 0 to 11.
pe pe-id / all Enter the keyword pe and the port extender ID or type the
option all to select all port extenders. Range is from 0 to
255.
stack unit unit-
number
Enter the keyword stack-unit and the configuration is
applied to all the stack-units present in the PE.
852