Reference Guide
Version Description
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.3.1.0 Introduced the verbose option.
7.7.1.0 Introduced on the S-Series.
Example
Dell#offline stack-unit 3
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running
Diagnostics.
Please make sure that stacking is not configured for
Diagnostics execution.
If configured, the unit roles may change. The unit will become
standalone once diags are executed.
Also reboot/online command is necessary for normal operation
after the offline command is issued.
Proceed with Offline [confirm yes/no]:yes
Dell#diag stack-unit 3 level0
Warning - diagnostic execution will cause multiple link flaps
on the peer side - advisable to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
Related
Commands
• offline
• online
offline
Place the PE stack-unit in the offline state to run the diagnostics tests.
C9000 Series
Syntax
offline stack-unit unit-number
Parameters
stack-unit slot-id Enter the keyword stack-unit and specify the stack-unit
number. The stack-unit number range is from 0 to 7.
Defaults none
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms,
see the relevant Dell Networking OS Command Line Reference Guide.