Reference Guide
0x4ab86020 18560 1856 10000 0.00% 0.00% 0.00% 0 tExcTask
0x4ab57020 20 2 10000 0.00% 0.00% 0.00% 0 tLogTask
0x4ab36020 9040 904 10000 0.00% 0.00% 0.00% 0 tUsrRoot
0x4068f020 100 10 10000 0.00% 0.00% 0.00% 0 main
0x4bea8020 0 0 0 0.00% 0.00% 0.00% 0 poePortScan
0x4c60c020 1060 106 10000 0.00% 0.00% 0.00% 0 V6RadAgent
0x4c5f3020 200 20 10000 0.00% 0.00% 0.00% 0 brAgent
0x4c5dd020 0 0 0 0.00% 0.00% 0.00% 0 nvProcessMwpAck
0x4c5c7020 40 4 10000 0.00% 0.00% 0.00% 0 IpAgent
0x4beab020 2890 289 10000 0.00% 0.00% 0.00% 0 nvAgent
0x4be93020 3700 370 10000 0.00% 0.00% 0.00% 0 l2ProcMwpAck
0x4bd6e020 5150 515 10000 0.00% 0.00% 0.00% 0 L2Agent
0x4bd55020 80 8 10000 0.00% 0.00% 0.00% 0 dsagt
0x4bd39020 0 0 0 0.00% 0.00% 0.00% 0 ifaDispatch
0x4bb4f020 10440 1044 10000 0.00% 0.17% 0.20% 0 ifagt_1
0x4baa8020 450 45 10000 0.00% 0.00% 0.00% 0 aclAgent
0x4ba74020 1740 174 10000 0.00% 0.00% 0.00% 0 sflPEAgt
0x4ba72020 680 68 10000 0.00% 0.00% 0.00% 0 count
0x4c679020 8620 862 10000 0.00% 0.00% 0.00% 0
Example: show
processes cpu
summary
Dell#show processes cpu summary
CPU utilization 5Sec 1Min 5Min
----------------- ------- ------- --------
CP 43% 42% 40%
RP 0% 0% 0%
show processes ipc
Display the IPC messaging used internally between Dell Networking OS processes.
C9000 Series
Syntax
show processes ipc [recv-stats | send-stats] [cp | rp | lp | pe
{slot-id | all}]
Parameters
recv-stats Enter the keyword recv-stats to display information on
IPC receiver-side messages.
send-stats Enter the keyword send-stats to display information on
IPC sender-side messages.
cp Enter the keyword cp to view IPC message statistics on the
Control Processor CPU.
rp Enter the keyword rp to view IPC message statistics on the
Route Processor CPU.
lp slot-id Enter the slot ID of the line card for which you want to view
IPC message statistics. The range of switch slot IDs is from 0
to 11. Enter linecard all to view IPC statistics for all line
cards.
pe pe-id Enter the keyword pe to view IPC message statistics on the
port extender (PE) .The PE ID range is from 0 to 255.
Control and Monitoring
133