Reference Guide

Version Description
9.2(1.0) Introduced on the Z9500.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.2.1.1 Introduced on the E-Series.
Usage Information
Untagged interfaces can only belong to one VLAN.
In the Default VLAN, you cannot use the no untagged interface command. To
remove an untagged interface from all VLANs, including the Default VLAN, enter
INTERFACE mode and use the no switchport command.
Related
Commands
interface vlan — configures a VLAN.
tagged — specifies which interfaces in a VLAN are tagged.
Far-End Failure Detection (FEFD)
The Dell Networking operating software supports far-end failure detection (FEFD) on the Ethernet
interfaces.
The FEFD feature detects and reports far-end link failures.
FEFD is not supported on the Management interface.
During an RPM failover, FEFD is operationally disabled for approximately 8 to 10 seconds.
By default, FEFD is disabled.
debug fefd
Enable debugging of FEFD.
C9000 Series
Syntax
debug fefd {events | packets} [interface]
To disable debugging of FEFD, use the no debug fefd {events | packets}
[interface] command.
Parameters
events Enter the keyword events to enable debugging of FEFD
state changes.
1250
Layer 2