Reference Guide

show linecard
output Field
Description
Next Boot Displays whether the line card is to be brought online at the
next system reload.
Required Type Displays the line card type configured for the slot. The
Required Type and Current Type must match. If they do not
match, use the linecard command to reconfigure the line
card type.
Current Type Displays the line card type installed in the slot. The Required
Type and Current Type must match. If they do not match,
use the linecard command to reconfigure the line card
type.
Hardware Rev Displays the chipset revision.
Num Ports Displays the number of ports in the line card.
Up Time Displays the number of hours and minutes the card is
online.
Dell Networking
OS Version
Displays the operating software version.
Jumbo Capable Displays Yes or No indicating if the line card can support
Jumbo frames.
Boot Flash Ver Displays the two possible Bootflash versions. The [Booted]
keyword next to the version states which version was used
at system boot.
Memory Size List the memory of the line card processor.
Temperature Displays the temperature of the line card. Minor alarm status
if the temperature is over 65° C.
Power Status Lists the type of power modules used in the chassis:
AC = AC power supply
DC = DC Power Entry Module (PEM)
Voltage Displays OK if the line voltage is within range.
Serial Number Displays the line card serial number.
Part Num Displays the line card part number.
Vendor ID Displays an internal code, which specifies the manufacturing
vendor.
Date Code Displays the line card’s manufacturing date.
Example (C9010)
Dell#show linecard 0
-- Linecard 0 --
Status : online
Next Boot : online
Control and Monitoring
125