Users Guide

Port Extender (PE) Stacking
You can stack up to eight C1048P port extenders using the mini-SAS stack ports on the back panel. The C1048P supports
stacking only with other C1048P port extenders. Stacking is
not supported on C9010 switches. To set up a PE stack, follow the
installation procedure in the Dell Networking C1048P Getting Started Guide or Dell Networking C1048P Installation Guide.
Each C1048P has 48 user ports, two uplink ports, and two stack-ports. When you connect multiple C1048Ps together through
the stack ports, they operate as a single unit with up to 384 front panel ports. The port extender stack operates and is managed
as a single entity through a C9000 Series switch.
Provision individual C1048Ps by entering commands in PE Configuration mode from a C9010 console. The PE configuration is
applied to a C1048P following its discovery and successful authentication by the parent C9010.
If the master unit in a PE stack fails, stack ownership transfers to the standby unit. If a standby unit fails, the stack master does
not experience interrupted operation. A new standby unit is elected from the other member units.
Topics:
Stack Management Roles
Stack Master Election
Important Points to Remember
PE Stack Configuration
Locating the Port Extender
Troubleshooting a PE Stack
Stack Management Roles
After you assemble and cable a stack of port extenders and power the stack units on, the units receive the provisioned
configuration from the parent C9010. A stack master unit is elected based on the highest MAC address.
The master may occupy any position in the stack. The Master LED on the front panel is illuminated on the master unit.
The stack unit with the second highest MAC address is elected as the standby or backup management unit. The standby
assumes the master role if the master unit in the stack fails. The PE with the next highest priority or MAC address becomes
standby. All remaining stack units function as stack members.
Although the master and standby units are automatically selected by MAC address, you can configure PE priorities to specify
which units are assigned the master and standby roles.
Stack Master Election
When a PE stack reloads and all stack units come up, all units participate in the stack master election. The master and standby
units are chosen based on the priority or MAC address. The stack takes the MAC address of the master unit.
Unit priority — The range is from 1 to 14. The unit with the highest priority is elected the master management unit; the unit
with the second highest priority is elected the standby unit. The default is 0. To remove a priority and set the priority to 0,
enter the no stack-unit unit-number priority command in PE CONFIGURATION mode.
MAC address (if there is a priority tie) — By default, the unit with the highest MAC value becomes the master unit if no
priorities are configured.
A change in the stack master occurs when:
41