Users Guide

pe State: Standby
Peer pe stack unit ID: 2
pe SW Version: 1-0(0-4074)
-- pe Redundancy Configuration --
------------------------------------------------
Primary pe: mgmt-id 0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot pe: Disabled
Auto failover limit: 3 times in 60 minutes
-- pe Failover Record --
------------------------------------------------
Failover Count: 0
Last failover timestamp: None
Last failover Reason: None
Last failover type: None
-- Last Data Block Sync Record: --
------------------------------------------------
stack-unit Config: succeeded Jun 30 2015 15:26:47
Runtime Event Log: succeeded Jun 30 2015 15:26:47
Running Config: succeeded Jun 30 2015 15:26:47
Removing a Unit from a PE Stack
In a PE stack, the parent C9010 synchronizes the software configuration on all stack units. A stack member
that is disconnected from the stack maintains this configuration.
To remove a stack member from the stack, disconnect the stacking cables from the unit. You may disconnect
the cable at any time, whether the unit is powered or unpowered, online or offline.
Examples of Removing a PE Stack Member
The following example shows the status of stack-unit 1 before it is removed from the PE stack.
Dell#show pe 0 system brief
Stack MAC : 00:01:e8:8a:df:e6
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-----------------------------------------------------------
0 Management online C1048P C1048P 1-0(0-4149) 52
1
Member online C1048P C1048P 1-0(0-4149) 52
2 Member not present
3 Standby online C1048P C1048P 1-0(0-4149) 52
4 Member not present
5 Member not present
6 Member not present
7 Member not present
The following example displays the status of stack-unit 1 after it is removed from the PE stack.
Dell#show pe 0system brief
Stack MAC : 00:01:e8:8a:df:e6
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
-------------------------------------------------------
Port Extender (PE) Stacking 852