Release Notes
Closed with Code Change Defects in Fabric OS v7.0.1
Fabric OS v7.0.1 Release Notes v1.0 Page 48 of 67
Defect ID: DEFECT000362362
Technical Severity: Medium
Summary: FC16-32 blade fails POST (FAULTY-51)
Symptom: After power cycling an 8510, FC16-32 port blade is set to Faulty-51.
Workaround: Power cycle the blade or the chassis
Feature: Diagnostics
Function: Post Diags
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000363516
Technical Severity: Medium
Summary: "tracestore" thread hogging CPU for extensive periods of time after executing a polling
script.
Symptom: "tracestore" thread has high CPU utilization for extensive periods of time.
Feature: Field Escalation
Function: OS: Infrastructure
Probability: Medium
Found in Release: FOS6.3.1
Service Request ID: 647161
Defect ID: DEFECT000363608
Technical Severity: Medium
Summary: Parity error detected on FCOE switch during supportsave collection
Symptom: Switch might fault during supportsave when non-significant parity errors were detected.
This only impacts FCOE switches
Feature: Field Escalation
Function: ASIC Driver
Probability: Low
Found in Release: FOS6.3.2
Where Else Fixed: FOS6.4.2 b GA
Defect ID: DEFECT000364788
Technical Severity: Medium
Summary: Unreliable speed negotiation may be encountered when BR5470 Cu ports are connected to
a 3rd party HBA.
Symptom: 3rd party HBA's are not properly negotiating to the correct speeds
Feature: 8G ASIC Driver
Function: PORT
Probability: Medium
Found in Release: FOS6.3.2
Where Else Fixed: FOS6.4.2 b GA
Defect ID: DEFECT000366323
Technical Severity: Medium
Summary: FICON - IEBCOPY job fails during read pipelining on the Brocade 7800/FX8-24 blade.
Symptom: IEBCOPY may fail when read pipelining is enabled. Other tape jobs will not be impacted
Feature: FCIP
Function: Emulation
Probability: High
Found in Release: FOS6.4.0
Service Request ID: 658691