Release Notes
Fabric OS v7.0.1 Release Notes v1.0 Page 21 of 67
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8
(For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications
in the 8510-8 Backbone Hardware Reference Manual)
Number of Ports
Blades
Type of Blade
DCX 8510-8 @110
VAC (Redundant
configurations)
DCX 8510-8
@200-240 VAC
(Redundant
configurations)
Comments
Any combination
of 8Gb or 16Gb
ports with QSFP
ICLs
FC8-64, FC16-
32
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
256 16Gb ports +
QSFP ICLs
FC16-32,
FC16-48
(Maximum of
fully
populated
FC16-32
blades)
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
Max 8 FC16-32 port
blades
192 16Gb Ports &
max 2 intelligent
boards (FX8-24
/FS8-
18/combination)
with QSFP ICLs
FC16-32,
FC16-48,
FX8-24, FS8-
18
Port /
Intelligent
Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
Max four FC16-48
port blades and max
2 Intelligent blades
336 16Gb ports +
QSFP ICLs
FC16-48
(Maximum of
seven FC16-
48 blades,
with one
empty port
blade slot)
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
Max 7 FC16-48 port
blades
384 16Gb ports +
QSFP ICLs
FC16-32,
FC16-48
Port Blade
Not Supported
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC
Power Supplies are
required
Any combination
of 8Gb or 16Gb
ports and
intelligent blades
with QSFP ICLs
FC16-32,
FC16-48, FC8-
64, FS8-18,
FX8-24
Intelligent
Blade
/Combination
Not Supported
4 Power
Supplies
For DCX 8510-8, four
(2+2)
1
220V AC
Power Supplies are
required when any
special purpose
blade are installed
1
When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for switch
marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this value if the current
value is set to zero. In FOS v7.0.x, the default setting for the marginal state due to missing power supplies is incorrectly
set to zero (Defect 000349586), which will prevent Fabric Watch from generating notifications when the switch enters
the marginal state due to missing power supplies.