Reference Guide

Fabric OS Command Reference 795
53-1002921-02
portDPortTest
2
-payload payload_pattern
Specifies the user defined payload pattern in integer.
-fec
Enables the forward error correction(FEC) during D-Port test. This sub-option is
not supported on D_Ports configured with Dense Wavelength Division
Multiplexing (DWDM).
-cr
Enables the credit recovery(CR) during D-Port test.
--setarg
Sets the D_Port test parameters and exits. The sub-options of --setarg are same
as --start.
--stop
Terminates the diagnostics on the specified D_Ports. Brocade recommends that
you execute this command on both the local port and the remote port to properly
terminate the D_Port tests.
--restart
Restarts the D_Port diagnostic tests with the configured parameters.
--show
Displays runtime status and results of the diagnostics.
--help
Displays the command usage.
EXAMPLES To initiate the D_Port test on a single port:
switch:admin> portdporttest --start
To terminate the D_Port test on a single port:
switch:admin> portdporttest --stop
To display the D_Port test results for a port while the test is in progress or after the test has completed:
switch:admin> portdporttest --show 42
D-Port Information:
==============================================
Port: 42
Remote WWNN: 10:00:00:05:1e:e5:e4:00
Remote port: 343
Mode: Manual
No. of test frames: 12 Million
Test frame size: 1024 Bytes
Pattern: JTSPAT
FEC (enabled/option/active): Yes/No/No
CR (enabled/option/active): No/No/No
Start time: Mon Jan 16 05:57:52 2012
End time: Mon Jan 16 05:58:56 2012