Reference Guide
Fabric OS Command Reference 771
53-1002921-02
portCfgShow
2
NPIV PP Limit 126 126 126 126 126 126 126 126 [truncated]
QOS E_Port - - - - - - - - [truncated]
Fport Buffers - - - - - - - - [truncated]
Port Auto Disable - - - - - - - - [truncated]
[output truncated]
To display port configuration settings for a single FCoE port on a DCX with a Brocade FCOE10-24 blade:
switch:admin> portcfgshow 12/4
Area Number: 116
Speed Level: 10G
AL_PA Offset 13: OFF
RSCN Suppressed OFF
NPIV PP Limit: 126
To display the QoS configuration for an EX_Port (QoS over FCR deployment):
switch:admin> switchshow | grep EX-Port
16 16 id N4 Online FC EX-Port \
10:00:00:05:1e:41:4a:45 "Tom_100"
(fabric id = 25 )(Trunk master)
switch:admin> portcfgshow 16
Area Number: 11
Octet Speed Combo: 1(16G|8G|4G|2G)
Speed Level: AUTO(HW)
Fill Word(On Active) 0(Idle-Idle)
Fill Word(Current) 0(Idle-Idle)
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance LS
VC Link Init OFF
Desired Distance 10 Km
Reserved Buffers 86
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable OFF
NPIV capability ON
QOS E_Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port ON
Mirror Port OFF
Credit Recovery ON
F_Port Buffers OFF
NPIV PP Limit: 126
CSCTL mode: OFF
Fault Delay 1(1.2sec)
D-Port mode: ON
D-Port over DWDM: ON
FEC active