Configuration au niveau du système
Manuel d'utilisation NetXtreme-E
• P1 : configuration port 1
• P2 : configuration port 2
• AN : négociation automatique
• No AN : vitesse forcée
Tableau 24 : Combinaisons de vitesses de liaison prises en charge
Port1 Link Speed
Setting
Port 2 Link Setting
Forced 1G Forced 10G Forced 25G AN Enabled {1G}
AN Enabled
{10G}
AN Enabled
{25G}
AN Enabled {1/
10G}
AN Enabled {1/
25G}
AN Enabled {10/
25G}
AN Enabled {1/10/
25G}
Forced 1G P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN
P2: no AN P2: no AN P2: no AN P2: {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {10/25G} P2: AN {1/10/25G}
Forced 10G P1: no AN P1: no AN Not supported P1: no AN P1: no AN Not supported P1: no AN P1: no AN P1: no AN P1: no AN
P2: no AN P2: no AN P2: {1G} P2: {10G} P2: AN {1/10G} P2: AN {1G} P2: AN {10G} P2: AN {1/10G}
Forced 25G P1: no AN Not supported P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN P1: no AN
P2: no AN P2: no AN P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {1/25G} P2: AN {25G} P2: AN {1/25G}
AN Enabled
{1G}
P1: {1G} P1: {1G} P1: {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G} P1: AN {1G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {10/25G} P2: AN {1/10/25G}
AN Enabled
{10G}
P1: AN {10G} P1: AN {25G} Not supported P1: AN {10G} P1: AN {10G} Not supported P1: AN {25G} P1: AN {10G} P1: AN {10G} P1: AN {10G}
P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {1G} P2: AN {1G} P2: AN {10G} P2: AN {1/10G}
AN Enabled
{25G}
P1: AN {25G} Not supported P1: AN {25G} P1: AN {25G} Not supported P1: AN {25G} P1: AN {1/10G} P1: AN {25G} P1: AN {25G} P1: AN {25G}
P2: no AN P2: no AN P2: AN {1G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {25G} P2: AN {1/25G}
AN Enabled
{1/10G}
P1: AN {1/10G} P1: AN {1/10G} P1: AN {1G} P1: AN {1/10G} P1: AN {1/10G} P1: AN {1/10G} P1: AN {1/25G} P1: AN {1G} P1: AN {1/10G} P1: AN {1/10G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1G} P2: AN {10G} P2: AN {1/10G}
AN Enabled
{1/25G}
P1: AN {1/25G} P1: {1G} P1: AN {1/25G} P1: AN {1/25G} P1: AN {1G} P1: AN {1/25G} P1: AN {10/25G} P1: AN {1/25G} P1: AN {1/25G} P1: AN {1/25G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {25G} P2: AN {1/25G}
AN Enabled
{10/25G}
P1: AN {10/
25G}
P1: {10G} P1: AN {25G} P1: AN {10/25G} P1: AN {10G} P1: AN {25G} P1: AN {1/10/25G} P1: AN {25G} P1: AN {10/25G} P1: AN {10/25G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {25G} P2: AN {10/25G} P2: AN {1/10/25G}
AN Enabled
{1/10/25G}
P1: AN {1/10/
25G}
P1: {1/10G} P1: AN {1/25G} P1: AN {1/10/
25G}
P1: AN {1/10G} P1: AN {1/25G} P1: AN {1/10/25G} P1: AN {1/25G} P1: AN {1/10/25G} P1: AN {1/10/25G}
P2: no AN P2: no AN P2: no AN P2: AN {1G} P2: AN {10G} P2: AN {25G} P2: AN {1/10G} P2: AN {1/25G} P2: AN {10/25G} P2: AN {1/10/25G}
Remarque : Utilisez un émetteur-récepteur optique pris en charge ou un câble en cuivre d'attache
directe pour atteindre la vitesse de liaison 1 Gbit/s.