Users Guide
LC log displays fan unavailability error
Issue: LC log displays The BOSS-S2 device does not have a fan installed in it error
message.
Probable Cause: Currently there is no fan requirement for BOSS-S2, which might be required in future based on M.2
thermal requirement.
Corrective
Action:
No action required. This error message can be ignored.
Physical disk size is not updated on iDRAC when
CSIOR is disabled
Probable Cause: When Collect System Inventory on Reboot (CSIOR) is disabled, iDRAC displays partial information about
BOSS-S2 components.
Corrective
Action:
Ensure that CSIOR is enabled in iDRAC for the server to collect the system inventory on reboot.
NOTE: Ensure that the BOSS-S2 controller firmware and iDRAC firmware are updated to the latest
version.
Physical disk or virtual disk is indicated as missing on
iDRAC when CSIOR is disabled
Probable Cause:
When Collect System Inventory on Reboot (CSIOR) is disabled, iDRAC displays partial information about
BOSS-S2 components.
Corrective
Action:
Ensure that CSIOR is enabled in iDRAC for the server to collect the system inventory on reboot.
NOTE: Ensure that the BOSS-S2 controller firmware and iDRAC firmware are updated to the latest
version.
The Back Ground Activity (BGA) task process in HII
does not report real-time status
Issue:
Back Ground Activity (BGA) task progress in HII does not report the real-time status of running tasks.
Probable Cause: This is an expected firmware behavior, and there is no functionality loss.
Corrective
Action:
It is recommended that you check the BOSS-S2 CLI for status.
NOTE: BOSS-S2 Command Line Interface (CLI) and Dell EMC Open Manage Storage Services only report events for the
tasks that are completed.
Virtual disk related events are repeatedly generated in
BOSS-S2 and OMSS
Issue:
Events related to virtual disk state will be generated twice in BOSS-S2 CLI and Open Manage Storage
Services (OMSS).