Reference Guide

age ageTagEWS
pdmLocaleLangu
age
pdmLocaleLangu
ageTagOSD
.1.3.6.1.4.1.2699.2.4.1.15.3.0 String R DEFVAL { en-US }
pdmLocaleLangu
age
pdmLocaleLangu
ageTagWSM
.1.3.6.1.4.1.2699.2.4.1.15.4.0 String R DEFVAL { en-US }
pdmAudio
pdmAudioDescri
ption
.1.3.6.1.4.1.2699.2.4.1.16.1.0 String R DEFVAL { "" }
pdmAudio
pdmAudioVolum
e
.1.3.6.1.4.1.2699.2.4.1.16.2.0 Integer R/W
pdmAudio pdmAudioMute .1.3.6.1.4.1.2699.2.4.1.16.3.0 Integer R/W
1. Muted
2. Not Muted
pdmAudio pdmAudioTreble .1.3.6.1.4.1.2699.2.4.1.16.4.0 Integer R DEFVAL { 0 }
pdmAudio pdmAudioBass .1.3.6.1.4.1.2699.2.4.1.16.5.0 Integer R DEFVAL { 0 }
pdmAudio
pdmAudioBalanc
e
.1.3.6.1.4.1.2699.2.4.1.16.6.0 Integer R DEFVAL { 0 }
pdmAlert pdmAlertIndex 1.3.6.1.4.1.2699.2.4.1.18.1.1.1.1 Integer not-accessible 1
pdmAlert
pdmAlertGroupT
ype
1.3.6.1.4.1.2699.2.4.1.18.1.1.2.1 String R See Note 1
pdmAlert
pdmAlertGroupI
d
1.3.6.1.4.1.2699.2.4.1.18.1.1.3.1 String R See Note 1
pdmAlert pdmAlertCode 1.3.6.1.4.1.2699.2.4.1.18.1.1.4.1 String R DEFVAL { "" }
pdmAlert
pdmAlertDescrip
tion
1.3.6.1.4.1.2699.2.4.1.18.1.1.5.1 String R
Alert's condition has lamp
Fail, Lamp hours running out,
Projector Overheating, Lamp
Overheating and Fan Error.
pdmAlert
pdmAlertSeverity
Level
1.3.6.1.4.1.2699.2.4.1.18.1.1.6.1 Integer R See Note 1
pdmAlert
pdmAlertTraining
Level
1.3.6.1.4.1.2699.2.4.1.18.1.1.7.1 Integer R DEFVAL { 2 }
pdmAlert
pdmAlertDateTim
e
1.3.6.1.4.1.2699.2.4.1.18.1.1.8.1 String R
DEFVAL
{ "1980-01-01T00:00:00" }
pdmAlert
pdmAlertPower
OnCount
1.3.6.1.4.1.2699.2.4.1.18.1.1.9.1 String R DEFVAL { "" }
pdmAlert
pdmAlertSysUpti
me
1.3.6.1.4.1.2699.2.4.1.18.1.1.10.1 String R DEFVAL { "" }
pdmAlert
pdmAlertCritical
AlertsCount
1.3.6.1.4.1.2699.2.4.1.18.2.0 Integer R
pdmAlert
pdmAlertAllAlerts
Count
1.3.6.1.4.1.2699.2.4.1.18.3.0 Integer R
Note 1:
a) If there is no any current alert, all of the OID in the alert table will respond with the default value.
pdmAlertGroupType =” “
pdmAlertGroupID = 0
pdmAlertSeverity = other (1)
The reset Object will respond default.
b) If there is a FAN alert the table is as shown below:
pdmAlertGroupType =” Fan”
pdmAlertGroupID = “Fan Error”
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
c) If there is a Lamp Fail alert, the table is as shown below:
pdmAlertGroupType = “Lamp”
pdmAlertGroupID= Lamp Fail
pdmAlertSeverity = Critical (3)
The rest Object will respond default.
d) If there is Projector Overheating alert, the table is as shown below:
pdmAlertGroupType = “ThermalSensor”
pdmAlertGroupID= “Projector Overheating”
pdmAlertSeverity = warning (4)
The rest Object will respond default.
Note 2:
1. Other
2. Unknown
3. VGA
4. DVI-D
5. DVI-I