Owner's Manual
Specification Prerequisite
Chassis IOM Configuration (if blade use case) Make sure that the SAN IOM is in access gateway
mode.
Managed Rack or Blade Servers Configuration Make sure that the QLogic FC Adapters installed in
any slot for rack servers or fabric B or C for blade
servers. ASM will query for WWPN values on a
QLogic QME or QLE 2662 or 2572 adapter.
Brocade Switch Configuration
• Create fault domain on Brocade switches for
Compellent.
• Create both physical and logical ports of the
Compellent array.
• Make sure active zone set is configured on the
Brocade SAN switches.
Compellent Storage Configuration Must be configured
Resource Discovery Make sure the following resources are discovered
in ASM.
• FC Servers for Deployment
• FC SAN Brocade Switch
• FC IOMs (Optional)
• Dell Compellent Storage
• VMware vCenter
Creating Template for ESXi Cluster Deployment
Create a new template with the following settings to deploy ESXi cluster using Dell Compellent storage
and Brocade (6505 or 6510) SAN switch.
• In the Template Builder page, add the following resources by clicking the corresponding components
icons.
– Storage
– Server
– Cluster
• To configure Brocade switches, perform the following actions:
a. In the Storage, click the corresponding storage component icon.
b. In the Storage Component pane, under Compellent Storage Settings, set the value as true for
Configure SAN Flag
parameter.
• The parameter iSCSI network is not required when deploying Fiber Channel storage. If this setting is
included, it will be ignored.
Related Links
Creating Template
Building Template Overview
Building and Publishing Template
46