Users Guide
c. Optionally, select Enable IPMI over LAN check box to enable or disable the IPMI over LAN channel for each iDRAC
present in the chassis.
8. To configure the unique chassis settings, click Next.
Related links
Adding or editing Chassis Management Controller (CMC) user
Adding or editing Integrated Dell Remote Access Controller (iDRAC) user
Configuring unique chassis settings
1. On the Unique Chassis Settings page of the Configure Chassis wizard, to modify the settings that are specific for each
individual chassis, select the Configure Unique Chassis Settings check box.
The Unique Chassis Settings page lists the chassis that you want to configure.
2. To configure a chassis, click the arrow left to the chassis title, and enter the following information:
• Chassis Name — Enter the name identify the chassis.
• CMC DNS Name — Enter DNS name of the chassis.
• FD332 Storage Node — For FX2 chassis, depending on your configuration, select one of the following options from the
FD332 Storage Node drop-down menu:
– Split Single Host
– Split Dual Host
– Joined
For FX2 chassis with FC430, select Split Dual Host.
For FX2 chassis with FC630, select Split Single Host.
• System Input Power Cap — Enter the maximum power limit that can be input to the system. You can specify the
maximum power limit in one of the following units:
– Watts — Automatically calculated during runtime.
– BTU/h — British Thermal Unit. For example, 16719.
– % — Type a value that indicates the actual percentage of power input versus the maximum power that can be
supplied.
3. Optionally, click Enter Location Details, and enter the following information:
• Datacenter — Indicates the name of the data center.
• Aisle — Indicates the name of the aisle.
• Rack — Indicates the name of the rack server.
• Rack Slot — Indicates the bottom rack slot of the chassis when it is mounted in the rack server.
Configuring unique server settings
1. On the Unique Server Settings page of the Configure Chassis wizard, to modify the settings for the servers within the
chassis, select Configure Unique Server Settings check box.
The Unique Server Settings page lists the servers within the chassis that you have selected. Each section in this page
represents a chassis and servers within that chassis. Click the arrow next to the section title to expand or collapse the section.
The following information is displayed for each server:
• Service Tag — Displays the service tag for the server. The service tag is a unique identifier provided by the manufacturer
for support and maintenance. If the server is absent, this field is empty.
• Slot — Identifies the server location.
• Management IP — Displays the management IP address of the server.
2. If you want to modify the iDRAC DNS Name of the server, in the iDRAC DNS Name column, enter an iDRAC DNS name for
the server.
76