Users Guide
To edit a user account, select a CMC user from the list, and click Edit. To delete a user account, select the user accounts
from the list, and click Delete.
b. To add new Integrated Dell Remote Access Controller (iDRAC) user, under iDRAC Users, click Create. For more
information, see Adding Or Editing An Integrated Dell Remote Access Controller (iDRAC) User.
4. Under Global Settings, in the Monitoring section, configure the following settings:
a. To set SNMP trap alert destination, perform the following steps:
1. Under Alert Destinations, to add an SNMP trap alert destination for chassis, click Create.
To edit Alert Destinations, select an alert destination from the list, and click Edit. To delete an alert destination, select
an alert destination from the list, and click Delete.
2. Enter a valid Destination IP Address. Use the quad-dot IPv4 format (for example, 10.10.10.10) or Fully Qualified
Domain Name (for example, dell.com).
3. Enter the Community String to which the destination management station belongs.
b. In the Email Alert Settings section, to configure the CMC to send email alerts to one or more email addresses:
1. In the SMTP Server box, enter the IP address or host name of an SMTP Server that receives email alerts.
2. Click Create and enter the following:
• In the Name box, enter the source email name from which the email alerts are sent.
• Enter one or more Destination Email Addresses.
c. In the Syslog Configuration (for I/O Modules only) section, enter the Syslog Destination IP Address to send I/O
module log messages to a Syslog Destination.
5. Under Global Settings, in the NTP section:
a. Enter the Time Zone in which the chassis is located.
b. To synchronize the chassis clock with an NTP server, select Enable NTP Server check box and enter the host names or
IP addresses of the Primary NTP Server and Secondary NTP Server (Optional).
6. Under Global Settings, in the Power Config section:
a. From the Redundancy Policy drop-down list, select one of the power redundancy policies that you want to configure on
the chassis:
• No Redundancy — The chassis is not configured with power redundancy.
• Power Supply Redundancy — A PSU in the chassis is kept as a spare, ensuring that the failure of any one PSU does
not cause the servers or chassis to power down.
• Grid Redundancy — This policy divides the available PSUs into two power grids. PSU 1 is power grid 1 and PSU 2 is
power grid 2. For maximum power, the PSUs should have the same capacity. If a grid or PSU fails, then the power is
provided by the remaining PSU.
b. Optionally, select Server Performance Over Power Redundancy check box to favor server performance and power up
over maintaining power redundancy.
c. Optionally, select Enable Dynamic Power Supply Engagement check box to allow the chassis controller to put
underutilized PSUs into standby mode based on the redundancy policy and system power requirements.
7. Under Global Settings, in the Networking section:
a. Optionally, select Register Chassis Controller on DNS check box to enable users to access the Chassis Management
Controller (CMC) with a user-friendly name, instead of an IP address.
b. Optionally, select Register iDRAC on DNS check box to enable users to access the Integrated Dell Remote Access
Controller (iDRAC) with a user-friendly name, instead of an IP address.
75