Users Guide
Table 10. ESXi cluster deployment pre-requisites
Specification Pre-requisite
Chassis IOM Configuration (if blade use case) Make sure that the SAN IOM is in access gateway mode.
Managed Rack or Blade Servers Configuration Make sure that the QLogic FC Adapters installed in any slot for
rack servers or fabric B or C for blade servers. ASM queries for
WWPN values on a QLogic QME or QLE 2662 or 2572 adapter.
Brocade Switch Configuration
• Create fault domain on Brocade switches for Compellent.
• Create both physical and logical ports of the Compellent
array.
• Make sure active zone set is configured on the Brocade
SAN switches.
Compellent Storage Configuration Must be configured
Resource Discovery Make sure the following resources are discovered in ASM.
• FC Servers for Deployment
• FC SAN Brocade Switch
• FC IOMs (Optional)
• Dell Compellent Storage
• VMware vCenter
Creating template for ESXi cluster deployment
Create a template with the following settings to deploy ESXi cluster using Dell Compellent storage and Brocade 6510 SAN switch.
• In the Template Builder page, add the following resources by clicking the corresponding components icons.
– Storage
– Server
– Cluster
• To configure Brocade switches, perform the following actions:
a. In the Storage, click the corresponding storage component icon.
b. In the Storage Component pane, under Compellent Storage Settings, set the value as true for Configure SAN Flag
parameter.
• The parameter iSCSI network is not required when deploying Fibre Channel storage. If this setting is included, it is ignored.
Related links
Creating template
Building template overview
Building and publishing template
Deploying service on ESXi clusters
On the Templates page, select the template created for this use case and click Deploy Service.
ASM performs the following actions when you deploy this service:
• Identifies the necessary servers from the FC server pool specified.
• Boots the server when if it is turned on and verifies the FC connectivity.
63