Install Guide
Resource Prerequisites
vsan 2 interface vfc101
vsan 2 interface vfc102
vsan 2 interface fc2/1
vsan 2 interface fc2/2
NOTE: All the Dell Compellent ports need
to part of the same VSAN.
Brocade
• Alias needs to be created having Dell
Compellent fault domain WWPN accessible on
Brocade switch. Create a single alias including
the virtual ports for the Compellent fault
domain, WWPN accessible on Brocade switch.
ASM automates the creation of each additional
zone for the server objects and place them into
a zone config.
• Brocade root password needs to be changed
so that the banner presented to change the
default password does not impact ASM's ability
to ssh into the switch.
Dell Compellent
Nothing specific for ASM.
Prerequisites for Rack Server, Cisco Nexus, Brocade, and Dell Compellent
The following table describes the prerequisites for the FCoE solution offered using Rack Server, Cisco
Nexus, Brocade, and Dell Compellent. For more information, see http://en.community.dell.com/
techcenter/extras/m/white_papers/20387203
Table 10. Prerequisites for Rack Server, Cisco Nexus, Brocade, and Dell Compellent
Resource Prerequisites
Cisco Nexus
Following is the prerequisite for Cisco Nexus:
• Enable “npv” feature on the switch. You need to
reboot the switch and delete the old
configuration. (Ensure to back up the
configuration before enabling the feature).
conf
feature npv
• Enable required features.
feature fcoe
feature npiv
feature lacp
NOTE: On systems with Cisco Nexus B22
Fabric Extenders, internal ports 17-32 are
not supported hence, certain network
ports in some servers may not function
when used with this device.
27