Install Guide

Resource Prerequisites
vsan 2 interface vfc101
vsan 2 interface vfc102
vsan 2 interface fc2/1
vsan 2 interface fc2/2
NOTE: All the Compellent ports needs to
part of the same VSAN.
Compellent
Create fault domain as per Compellent best
practices.
Prerequisites for M1000e (with MXL), Cisco Nexus, Brocade, and Dell
Compellent
The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL),
Cisco Nexus, Brocade, and Dell Compellent.
Table 9. Prerequisites for M1000e (with MXL), Cisco Nexus, Brocade, and Dell Compellent
Resource Prerequisites
MXL DCB needs to be enabled.
VLT needs to be disabled.
FIP Snooping feature needs to be enabled on
the MXL.
conf
Feature fip-snooping
Port-channel member interfaces needs to have
following configuration.
interface range tengigabitethernet
0/33 – 36
port-channel-protocol lacp
port-channel 128 mode active
exit
protocol lldp
no advertise dcbx-tlv ets-reco
dcbx port-role auto-upstream
no shut
exit
Port-channel connecting Cisco Nexus switch
needs to have following configuration.
interface port-channel 128
portmode hybrid
switchport
fip-snooping port-mode fcf
Server facing ports needs to have following
configuration.
portmode hybrid
switchport
25