Install Guide
Prerequisites for Rack Server, Cisco Nexus, and Compellent
The following table describes the prerequisites for the FCoE solution offered using Rack Server, Cisco
Nexus and Compellent.
Table 8. Prerequisites for Rack Server, Cisco Nexus, and Compellent
Resource Prerequisites
Cisco Nexus
Following is the prerequisite for Cisco Nexus.
• Enable required features.
feature fcoe
feature npiv
feature lacp
NOTE: On systems with Cisco Nexus B22
Fabric Extenders, internal ports 17-32 are
not supported hence, certain network
ports in some servers may not function
when used with this device.
•
Create a new VSAN - instantiate it in the VSAN
database.
conf
vsan database
vsan <vsan id>
• Configure regular ethernet VLANs, and then the
FCoE VLAN is created with an assignment to its
respective VSAN.
vlan <fcoe vlan>
fcoe vsan <vsan>
• Instantiate but do not configure the upstream
port-channel (LAG) to the core /aggregation
switch.
• Instantiate but do not configure the
downstream port-channel (LAG) to the IOA4.
• Create the VFC interface to bind to the servers
CNA FIP MAC address. This can be located in
the CMC WWN table or the IDRAC page for the
server.
For Example
interface vfc101
bind mac-address 5C:F9:DD:16:EF:07
no shutdown
interface vfc102
bind mac-address 5C:F9:DD:16:EF:21
no shutdown
• Move back into the VSAN database and create
entries for the new VFC just created and create
entries for the FC port(s) that will be used.
vsan database
24