a. Optionally, select Register Chassis Controller on DNS check box to enable users to access the
Chassis Management Controller (CMC) with a user-friendly name, instead of an IP address.
b. Optionally, select Register iDRAC on DNS check box to enable users to access the Integrated
Dell Remote Access Controller (iDRAC) with a user-friendly name, instead of an IP address.
c. Optionally, select Enable IPMI over LAN check box to enable or disable the IPMI over LAN
channel for each iDRAC present in the chassis.
8. To configure the unique chassis settings, click Next.
Related Links
Adding or editing Chassis Management Controller (CMC) user
Adding or editing Integrated Dell Remote Access Controller (iDRAC) user
Configuring unique chassis settings
1. On the Unique Chassis Settings page of the Configure Chassis wizard, to modify the settings that are
specific for each individual chassis, select the Configure Unique Chassis Settings check box.
The Unique Chassis Settings page lists the chassis that you want to configure.
2. To configure a chassis, click the arrow left to the chassis title, and enter the following information:
• Chassis Name — Enter the name identify the chassis.
• CMC DNS Name — Enter DNS name of the chassis.
• System Input Power Cap — Enter the maximum power limit that can be input to the system. You
can specify the maximum power limit in one of the following units:
– Watts — Automatically calculated during runtime.
– BTU/h — British Thermal Unit. For example, 16719.
– % — Type a value that indicates the actual percentage of power input versus the maximum
power that can be supplied.
3. Optionally, click Enter Location Details, and enter the following information:
• Datacenter — Indicates the name of the data center.
• Aisle — Indicates the name of the aisle.
• Rack — Indicates the name of the rack server.
• Rack Slot — Indicates the bottom rack slot of the chassis when it is mounted in the rack server.
Configuring unique server settings
1. On the Unique Server Settings page of the Configure Chassis wizard, to modify the settings for the
servers within the chassis, select
Configure Unique Server Settings check box.
The Unique Server Settings page lists the servers within the chassis that you have selected. Each
section in this page represents a chassis and servers within that chassis. Click the arrow next to the
section title to expand or collapse the section.
The following information is displayed for each server:
• Service Tag — Displays the service tag for the server. The service tag is a unique identifier
provided by the manufacturer for support and maintenance. If the server is absent, this field is
empty.
• Slot — Identifies the server location.