Users Guide
Advanced Fabric Design – Advanced Aggregation Config
The Advanced Aggregation Config screen displays the default values for the fabric uplinks and VLTi links.
Uplinks connect the fabric from the next upstream tier of devices to the core of the network. The
minimum number of uplinks is two: one uplink is the active link and one uplink is for redundancy.
Figure 21. Advanced Aggregation Config
1. (Optional) To customize the switch names, enter a name in each of the Aggregation Names fields.
The default names are FabricName—Agg-1 and FabricName—Agg-2.
2. Select a switch type from the drop-down Aggregation Model menu:
• Z9000
• S6000
• S4810
• S4820T
The Number of switches field displays the number switches in the VLT pair.
3. In the Config Speed (Gb) section, configure the number of ports for uplinks and VLTi in the
appropriate entry fields.
NOTE:
• Configure at least two VLTi links and two uplinks.
• All values must be even.
• The maximum configurable bandwidth is 320 Gb.
• VLTi does not support 40G ⇨10G Split.
• The 40G ⇨10G Split uplink bandwidth range is 2–32.
• The 40G uplink bandwidth range is 2–8.
• The 10G uplink bandwidth range is 2–32 and is supported on S4810 and S4820T.
• The VLTi link range is 2–16.
The Allocated column displays the total amount of configured uplink bandwidth (in Gb).
4. Review the values and click Next to go to the Advanced Access Config screen.