Users Guide

load the correct software image configuration file for each type of switch from the TFTP/FTP site
during BMP. For information about BMP, refer to DHCP Integration.
The pool of IP addresses for the management port for each switch in the fabric.
The IP addresses (must be an even number) for the uplink configuration from the ISP service. The
uplink port number range is based whether a 10 Gb or 40 Gb bandwidth is selected.
For a 10 Gb bandwidth, AFM supports 2–32 uplinks.
For a 40 Gb bandwidth, AFM supports 2–8 uplinks.
The IP addresses or VLAN ID for the downlink configuration to connect to the server or ToR.
The protocol configuration for uplinks and downlinks.
Selecting a Layer 2 and Layer 3 with Resiliency (Routed VLT) Fabric Design
For workload migration over virtualized environments, use a Layer 2 VLT fabric design. To extend equal
cost multipathing capabilities, use the Layer 3 with Resiliency (Routed VLT) fabric .
AFM supports the following Layer 2 VLT and Layer with 3 with Resiliency (Routed VLT) fabric designs:
1 and 2 Tier 10 Gb for Layer 2 LAN/SAN for iSCSI
1 and 2 Tier for 10 Gb Layer 2 LAN/SAN for Fibre Channel
1 Tier for 10 Gb and 40 Gb ToR for Layer 2 and Layer 3 Resiliency (Routed VLT)
2 Tier and 3 Tier Topologies for 1 Gb ToR VLT Deployment for Layer 2 and Layer 3 with Resiliency
(Routed VLT)
10 Gb or 40 Gb Top of Rack Deployment (mVLT)
2 and 3 Tier 10 Gb ToR (mVLT) Deployment Topologies for Layer 2 or Layer 3 with Resiliency
10 Gb Blade Switch (MXL) for Layer 2 and Layer 3 with Resiliency (Routed VLT)
For information about tiers, refer to Deployment Topology and Deployment Topology Use Cases.
For more information about VLT, refer to the following sections:
Overview of VLT
Key Core Design Considerations
Getting Started
One and Two-Tier ToR 10 Gb for Layer 2 LAN/SAN for iSCSI Topologies
Table 2. One-Tier ToR Layer LAN/SAN for iSCSI Topologies
Possible Topologies
DL BW UL BW UL Port
Range
iSCSI
Port
Range
DL Port
Range
AVC Aggregation Access
10G 10G 2–32 2–8 1–108 2 * 40G S4810 NA
10G 40G 2–4 2–8 1–102 2 * 40G S4810 NA
DL = Downlink
DL BW = Down Link Bandwidth
Supported Fabric Types
31