Users Guide
load the correct software image configuration file for each type of switch from the TFTP/FTP site
during BMP. For information about BMP, refer to DHCP Integration.
• The pool of IP addresses for the management port for each switch in the fabric.
• The IP addresses (must be an even number) for the uplink configuration from the ISP service. The
uplink port number range is based whether a 10 Gb or 40 Gb bandwidth is selected.
– For a 10 Gb bandwidth, AFM supports 2–32 uplinks.
– For a 40 Gb bandwidth, AFM supports 2–8 uplinks.
• The IP addresses or VLAN ID for the downlink configuration to connect to the server or ToR.
• The protocol configuration for uplinks and downlinks.
Selecting a Layer 2 and Layer 3 with Resiliency (Routed VLT) Fabric Design
For workload migration over virtualized environments, use a Layer 2 VLT fabric design. To extend equal
cost multipathing capabilities, use the Layer 3 with Resiliency (Routed VLT) fabric .
AFM supports the following Layer 2 VLT and Layer with 3 with Resiliency (Routed VLT) fabric designs:
• 1 and 2 Tier 10 Gb for Layer 2 LAN/SAN for iSCSI
• 1 and 2 Tier for 10 Gb Layer 2 LAN/SAN for Fibre Channel
• 1 Tier for 10 Gb and 40 Gb ToR for Layer 2 and Layer 3 Resiliency (Routed VLT)
• 2 Tier and 3 Tier Topologies for 1 Gb ToR VLT Deployment for Layer 2 and Layer 3 with Resiliency
(Routed VLT)
• 10 Gb or 40 Gb Top of Rack Deployment (mVLT)
• 2 and 3 Tier 10 Gb ToR (mVLT) Deployment Topologies for Layer 2 or Layer 3 with Resiliency
• 10 Gb Blade Switch (MXL) for Layer 2 and Layer 3 with Resiliency (Routed VLT)
For information about tiers, refer to Deployment Topology and Deployment Topology Use Cases.
For more information about VLT, refer to the following sections:
• Overview of VLT
• Key Core Design Considerations
• Getting Started
One and Two-Tier ToR 10 Gb for Layer 2 LAN/SAN for iSCSI Topologies
Table 2. One-Tier ToR Layer LAN/SAN for iSCSI Topologies
Possible Topologies
DL BW UL BW UL Port
Range
iSCSI
Port
Range
DL Port
Range
AVC Aggregation Access
10G 10G 2–32 2–8 1–108 2 * 40G S4810 NA
10G 40G 2–4 2–8 1–102 2 * 40G S4810 NA
DL = Downlink
DL BW = Down Link Bandwidth
Supported Fabric Types
31