Users Guide

Alarm Recommended Action
b. From the Deploy Fabric drop-down
menu, select Deploy and Validate.
c. Click the Validation tab and select the
switch.
d. Click Validate Selected.
Validation failed because the switch has a model
mismatch.
1. Verify that you have correctly mapped the
system MAC address to the associated
switches:
a. Navigate to the Network> Fabric Name >
Configure and Deploy screen.
b. From the Deploy Fabric drop-down
menu, select the Pre-deployment
Configuration option
c. Navigate to the Assign Switch Identities
screen and check the system MAC
address mapping for the associated
switches.
2. To verify changes, validate the switch:
a. Navigate to the Network > Fabric Name
> Configure and Deploy screen.
b. From the Deploy Fabric drop-down
menu, select Deploy and Validate.
c. Click the Validation tab and select the
switch.
d. Click Validate Selected.
Validation failed because the switch is in a
disconnected state.
The switch is not reachable. Verify the connectivity
of the switch.
Validation failed because Te 0/1 has a wiring
mismatch.
1. Review the wiring plan.
2. Wire according to the wiring plan to fix the
wiring mismatch.
3. Make sure that the ports on the switches are
mapped accurately.
Validation failed because Te 0/1 has a missing link. No connectivity is detected to the switch. Check
the cables.
Validation failed because only a partial link can be
verified for Te 0/1.
Check the connectivity of the link and the
connectivity of the switch.
Validation failed because the switch has a
configuration mismatch.
1. Navigate to the Network > Fabric Name >
Configure and Deploy screen.
2. Click Errors.
3. Select the Configuration Mismatch tab.
4. Review the configuration mismatch and
correct the configuration errors.
162
Troubleshooting