Users Guide

Aggregation Switch Deployment Type
VLT MLAG
S6000 NE
Z9500 NE
”NE” denotes non-endpoint switches that can extend with another tier.
The Number of switches field displays the number switches in the inter chassis pair.
3. (N3000 and N4000 series switch models only) Select an optional module type from the Optional
Module drop-down menu. Options vary based on the core switch type. Refer to the following table
for supported options.
Table 21. Core Config Optional Module Options
Switch Type and Mode Optional Module Supported Options
N3000 series 1/1/1 2 x 10 G — Fiber
2 x 10 G — Copper
N4000 series 1/1/1 4 x 10 G — Fiber
4 x 10 G — Copper
2 x 40 G — Fiber
None
NOTE: Select this option if you
do not have any optional
modules in this slot.
4. (Z9500 series switch model only) In the License Type field, select the number of ports licensed: 36
(default); 84; or 132.
NOTE:
AFM does not validate whether the specified number of licensed ports is correct for the
switch. An incorrect setting causes the fabric deployment to fail.
This setting applies for both members in VLT mode.
You can edit this value without restriction before beginning pre-deployment steps for the
switch. After pre-deployment begins, you can only edit the number of ports licensed
upwards (for example, 36–84).
5. The default switch names are FabricName—Core-1 and FabricName—Core-2. To customize the
switch names, enter a name in each of the
Switch Names fields.
6. In the Port Specification (per switch) section, configure the number of ports for uplinks, downlinks,
inter chassis links, or split ports, in the appropriate entry fields.
66
Designing a Fabric