Users Guide

FL BW AA = Fabric Link Bandwidth between Aggregation & Access
UL BW = Uplink Bandwidth
Use the following tables as guideline to select the appropriate two tier Layer 2 VLT or Layer 3 with
Resiliency (Routed VLT) fabric design for a 40 Gb ToR (mVLT deployment).
NOTE: With a Layer 2 VLT fabric, the uplinks come from the switches on the aggregation side. For
information about tiers, refer to Standard Fabric Design — Deployment Topology.
Table 11. Two Tier ToR (mVLT) — 40 G Downlinks for Layer 2 or Layer 3 with Resiliency (Routed VLT)
DL BW UL
BW
Type DL Port
Range
AVC Access
VLTi
Capacity
FL BW
AA
Possible Topologies
Aggregation Access
40 Gb 10 Gb Basic 60 -
870
2 * 40 Gb NA 80 Gb Z9000 Z9000
40 Gb 10 Gb Basic 60 -
870
2 * 40 Gb NA 80 Gb S6000 S6000
40 Gb 10 Gb Resiliency 60 - 784 2 *40 Gb 2 * 40 Gb 80 Gb Z9000 Z9000
40 Gb 10 Gb Resiliency 60 - 784 2 * 40 Gb 2 * 40 Gb 80 Gb S6000 S6000
40 Gb 40 Gb Basic 59 - 870 2 * 40 Gb NA 80 Gb Z9000 Z9000
40 Gb 40 Gb Basic 59 - 870 2 * 40 Gb NA 80 Gb S6000 S6000
40 Gb 40 Gb Resiliency 59 - 784 2 *40 Gb 2 * 40 Gb 80 Gb Z9000 Z9000
40 Gb 40 Gb Resiliency 59 - 784 2 *40 Gb 2 * 40 Gb 80 Gb S6000 S6000
Three Tier Topologies for a 10 Gb or 40 Gb ToR (mVLT) Deployment Layer 2 or Layer 3 with
Resiliency (Routed VLT)
Use the following tables as guideline to select the appropriate three tier Layer 2 VLT or Layer 3 with
Resiliency (Routed VLT) fabric design for a 40 Gb Tor (mVLT) Deployment.
NOTE: With a Layer 2 VLT fabric, the uplinks come from the switches on the aggregation side. For
information about tiers, refer to Standard Fabric Design — Deployment Topology.
AVC = Aggregation VLTi Capacity
CVC = Core VLTi Capacity
BW = Bandwidth
DL = Downlink
DL BW = Downlink Bandwidth
FL BW CA = Fabric Link Bandwidth between Core & Aggregation
Supported Fabric Types
35