Users Guide
Table 3. Two Tier ToR Layer 2 LAN/SAN for iSCSI Topologies
Possible Topologies
Uplink
Port
Range
iSCSI
Port
Range
Downlink
Port Range
Aggregation
VLTi Capacity
Access
VLTi
Capacity
FL BW
AA
Aggregation Access
2 - 32 2 - 8 71 - 3410 2 * 40G NA 20G S4810 S4810
2 - 4 2 - 8 101 - 3224 2 * 40G NA 20G S4810 S4810
2 - 32 2 - 8 71 - 2916 2 * 40G 2 * 40G 20G S4810 S4810
2 - 4 2 - 8 101 - 2808 2 * 40G 2 * 40G 20G S4810 S4810
2 - 32 2 - 8 71 - 2970 2 * 40G 2 * 40G 20G S4810 S4810
2 - 4 2 - 8 101 - 2808 2 * 40G 2 * 40G 20G S4810 S4810
FL BW AA = Fabric Link Bandwidth between Aggregation & Access
Table 4. Two Tier MXL for Layer 2 LAN/SAN for iSCSI Topologies
Possible Topologies
Uplink
Port
Range
Uplink
Bandwidth
Deployment
Type
iSCSI
Port
Range
MXL Blade
Pairs
Range
FL BW
AA
Aggregation Access
2 - 32 10G Basic 2 - 8 2 - 27 20G
S4810 MXL
2 - 4 40G Basic 2 - 8 2 - 26 20G
S4810 MXL
2 - 32 10G Stacking 2 - 8 2- 27 40G
S4810 MXL
2 - 4 40G Stacking 2 - 8 2 - 26 40G
S4810 MXL
2 - 32 10G MXL -
intraChassis
resiliency
2 - 8 2 -27 20G
S4810 MXL
2 - 4 40G MXL -
intraChassis
resiliency
2 - 8 2 - 26 20G
S4810 MXL
FL BW AA = Fabric Link Bandwidth between Aggregation & Access
Supported Fabric Types
27