Users Guide
For Power over Ethernet (PoE) ports, the following metrics are available:
• Power in Milliwatts
• Voltage in volts
• Current in MilliAmps
• Temperature in celsius
1. From the menu, click Network > Fabric Name > Switch Name and then make sure that the Summary
tab is selected.
2. Click the Performance tab at the bottom of the screen.
3. In the upper right of the screen, select the format for the data:
• Graphical
• Tabular
4. Select a data option:
• Real-Time Data
– If you select real-time data, select the interval real-time data collection (in seconds) from the
Interval (seconds) drop-down menu:
* 15
* 30
* 45
* 60
• Historical Data
– If you select historical data, select one of the following options from the Date Range drop-
down menu:
* Last 12 hours
* Last 24 hours
* Last 7 days
* Last 30 days
* Custom Date Range — Enter start and end dates
Data Collection
By default, AFM automatically enables data collection after deployment. To disable data collection for a
fabric:
1. From the Jobs menu, click the Data Collections tab.
2. Click Schedule Data Collection.
The Edit Data Collection window appears.
3. To disable data collection for a specific fabric, clear the check box for the fabric.
The Polling Rate is 15 minutes.
4. Click OK.
Threshold Settings
You can configure the monitoring link bundle and Threshold Crossing Alert (TCA) between the spine
switches and the leaf switches. You can access these settings by clicking Jobs on the menu and then
Performance Management
193