Hardware manual
Group Administration Group monitoring
15–18
Monitoring power supplies
A member has two or three power supplies. Most PS Series arrays use power supplies that have integrated cooling
modules.
A member can survive one power supply failure. Replace failed power
supplies as soon as possible.
For proper cooling, do not remove a power supply until you have a replacement.
For informat
ion about replacing a power supply
, see the Hardware Maintenance manual for your array model or
contact your PS Series support provider.
The Power Supplies panel shows the status of the power supplies. The n
umber and type of hardware components
shown depends on your array model.
Table 15-14 shows power supply status and possible solutions. The first column lists the status values
, the second
column provides descriptions, and the third column provides solutions.
T
able 15-14: Power Supply Status
Status Description Solution
OK Array is receiving power from the power supply. None needed; informational.
no-power Power supply is not installed or not connected to a
pow
er source, or t
he power supply is not turned on (not
all power supply models).
Keep all power supplies installed and connected to a
po
wer source. If the power supply has a power
switch, make sure the power switch is on.
failed Power supply failure. See your PS Series support provider for information
about replacing the power
supply.
Monitoring cooling and fans
A member has two or three cooling modules and multiple fans. Most PS Series arrays use power supplies that have
integrated cooling modules.
Periodically, feel the room temperature where the hardware is
located and make sure that the room is sufficiently
cool and ventilated. Also make sure the fan trays and cooling modules have no red LEDs, and monitor the member
temperature.
A member can survive one cooling module failure. Re
place failed cooling modules as soon as possible.
The Cooling Fans panel shows the status of the fans on the cooling modules. Table 15-15 shows the cooling fan
status. These status values apply to array models with combination
power supply and cooling modules. The first
column lists the status values, the second column provides descriptions, and the third provides solutions.
Table 15-15: Cooling Fan Status
Status Description Solution
fan-present Cooling modules and fan are functioning. None needed; informational.
fan-not-
present
Cooling module or fan failed, or the cooling
m
odule
is not installed, not turned on, or not
connected to a power source.
Install a functioning cooling module, make sure the
cooling
module is connected to a power source, or
turn on the cooling module (not available on all
cooling module models).
See your PS Series support provider for information
about replacing
a failed cooling module.