Service manual

Product spec and feature
2-26
Service Manual
• Fuser Voltage
□ Input Voltage : 24 V DC ± 15%
□ Output Voltage : 0V ~ 1KV DC ± 3%
□ Output Voltage Rising Time : 50 ms Max
□ Output Voltage Falling Time : 50 ms Max
□ Output Loading range : 10 MΩ ~ 100 MΩ
□ Output Control Signal(Fuser PWM) : CPU is HV output when PWM is Low
2) SMPS (Switching Mode Power Supply)
It is the power source of entire system. It is assembled by an independent module, so it is possible to use for
common use. It is mounted at the bottom of the set.
It is consisted of the SMPS part, which supplies the DC power for driving the system, and the AC heater
control part, which supplies the power to fuser. SMPS has two output channels. Which are 5V and +24V.
• AC Input
□ Input Rated Voltage : AC 220V - 240V AC 120V / AC 220V(EXP version)
□ Input Voltage fluctuating range : AC 198V - 264V AC 90V - 135V / AC 198V - 264V(EXP version)
□ Rated Frequency : 50-60 Hz
□ Frequency Fluctuating range : 47 - 63 Hz
□ Input Current : Under 6Arms / 2.4Arms (But, the status when lamp is off or rated voltage is
inputted/outputted )
• Rated Output Power
NO ITEM CH1 CH2
1 CHANNEL NAME +5V +24.0V
2 CONNECTOR PIN CON 3
5V PIN: 13,15,17,19
CON3
24V PIN
1,3,5,7,9
3 Rated Output +5V ±5%
(4.75~5.25V)
+24V ±10%
(21.6~26.4V)
4 Max. Output Current 4.0 A 7.5A
5 Peak Loading Current 4.4 A 8.0A
6 RIPPLE NOISE Voltage Undoer 100mVp-p Under 500mVp-p
7 Maximum output 20W 180W
8 Peak output 22W 192W
9 Protection for loading shortage
and overflowing current
4.5A~6.5A shutdown or
Fuse open
8.0A ~11A shutdown or
Fuse open