Datasheet
Document ID Number: 328209 003EN Intel
®
Xeon Phi™ Coprocessor Datasheet
23
Figure 3-6 Airflow Requirement vs. 45
o
C Inlet Temperature for the 5110P at 225W TDP
CardInlet(
o
C)
TotalFlow(ft^3/min) Primary(ft^ 3/min) Secondary(ft^3/min)
CarddP(inchH
2
O)
20 10.6 7 3.7 0.08
21 10.8 7.1 3.7 0.08
22 11 7.3 3.7 0.08
23 11.2 7.5 3.7 0.08
24 11.4 7.7 3.7 0.09
25 11.6 7.9 3.7 0.09
26 11.8 8.1 3.7 0.09
27 12 8.3 3.7 0.09
28 12.2 8.5 3.7 0.1
29 12.5 8.7 3.7 0.1
30 12.7 9 3.8 0.1
31 13 9.2 3.8 0.11
32 13.3 9.5 3.8 0.11
33 13.6 9.8 3.8 0.12
34 13.9 10.1 3.8 0.12
35 14.2 10.4 3.8 0.12
36 14.6 10.7 3.9 0.13
37 15 11.1 3.9 0.14
38 15.4 11.4 3.9 0.14
39 15.8 11.8 4 0.15
40 16.2 12.2 4 0.16
41 16.7 12.7 4.1 0.16
42 17.2 13.1 4.1 0.17
43 17.8 13.6 4.2 0.18
44 18.4 14.2 4.2 0.19
45 19.1 14.7 4.3 0.21