User Manual

Table Of Contents
1. Remove the standard cooling fans and install the High performance (silver grade) fan or high-performance (gold grade) fan
cooling fans.
NOTE: Refer to the cooling fan and foam requirement matrix for the cooling fan and foam requirement for different
configurations.
Table 79. Cooling fan and foam requirement matrix
System
configuration
Cooling fan Foam requirement
w/GPU w/GPU + Barlow Pass
DIMM
w/GPU w/GPU + Barlow Pass
DIMM
8 x 2.5-inch
NVMe
HPR SLVR HPR GOLD No Yes
16 x 2.5-inch
SAS/SATA
HPR GOLD HPR GOLD Yes Yes
16 x 2.5-inch
NVMe
HPR GOLD HPR GOLD Yes Yes
24 x 2.5-inch
SAS/SATA
HPR GOLD HPR GOLD Yes Yes
16 x 2.5-inch
SAS/SATA + 8 x
2.5-inch NVMe
HPR GOLD HPR GOLD Yes Yes
HPR - High Performance, SLVR - Silver
NOTE: For more information about supported cooling fans matrix, see the thermal restriction section in Dell EMC
PowerEdge R750 Technical Specifications on the product documentation page.
NOTE: 12 x 3.5 inch and rear drive configuration systems do not support GPU card.
2. Remove the heat sink and install the required t-type heat sink.
NOTE: All GPU cards require t-type heat sink and GPU shroud, irrespective of the length.
3. Remove the air shroud and install the GPU air shroud.
4. Remove the GPU air shroud top cover.
NOTE: The GPU air shroud top cover is part of the GPU air shroud.
5. Remove the GPU air shroud filler.
6. Install the GPU.
NOTE: See expansion card installation guidelines to know about risers and slots that support GPU.
NOTE: For information on riser slot location on the system board, see the System board jumpers and connectors topic.
7. If applicable, connect the power cables to the GPU. To know the connectors for GPU on the system board, see the System
board jumpers and connectors topic.
Refer to the GPU power cable matrix to know about the requirement of cable for the GPU.
Table 80. GPU power cable matrix
Category Description Type Vendor Cable Cable quantity
GPU CRD,GRPHC,NVIDIA,
T4, 16 GB, 70 W, L
HH and HL (FH and
LP brackets)
NVIDIA Not required Not required
GPU NVIDIA Volta Next
300 W DW GPU
(A100)-Gen 4
FH and FL NVIDIA 8-pin cable 1 piece per GPU riser
GPU Nvidia RTX-A40 FH and FL NVIDIA 8-pin cable 1 piece per GPU riser
GPU CRD,GRPHC,32 GB,
225 W, M10, PASSIV
FH and FL NVIDIA 6 + 2-pin cable 1 piece per GPU riser
HH - Half Height, HL - Half Length, FH - Full Height, FL - Full Length
Upgrade Kits 225