User Manual

Table Of Contents
Internal USB card kit
Serial COM port kit
VGA port kit
DPU kit
BOSS S2 module kit
The BOSS S2 module supports up to two M.2 SSDs.
NOTE: To enable the BOSS S2 module in the system, ensure that the BIOS firmware version is 1.5.5 and iDRAC firmware
version is 4.30.30.30 or later.
Before you begin the installation or removal process, follow the safety guidelines and before working inside the system
instructions.
Table 76. BOSS S2 module kit components
R750 (quantity) Components in kit
NA BOSS cover
1 M3 x 0.05 x 4.5 mm screws
1 BOSS signal cable
1 BOSS power cable
1 BOSS-S2 module
1 or 2* BOSS-S2 card carrier
1 or 2* M.2 SSD
2 M.2 240 GB information label
2 M.2 480 GB information label
1 BOSS card filler
1 Tech sheet
To remove the BOSS blank :
1. Power off the system and remove the system cover.
2. Use a screwdriver to push out the blank from the BOSS S2 module bay.
Upgrade Kits
221