User Manual
Table Of Contents
- Dell EMC PowerEdge R750 Installation and Service Manual
- Contents
- About this document
- System overview
- Initial system setup and configuration
- Minimum to POST and system management configuration validation
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Cable routing
- M.2 SSD module
- Optional front bezel
- System cover
- Drive backplane cover
- Air shroud
- Removing the air shroud
- Installing the air shroud
- Removing the GPU air shroud
- Installing the GPU air shroud
- Removing the GPU air shroud top cover
- Installing the GPU air shroud top cover
- Removing the GPU air shroud filler
- Installing the GPU air shroud filler
- Removing the rear drive module air shroud
- Installing the rear drive module air shroud
- Cooling fans
- Side wall brackets
- Drives
- Rear drive module
- Drive backplane
- PERC module
- System memory
- Processor and heat sink module
- Expansion cards and expansion card risers
- Expansion card installation guidelines
- Removing the expansion card risers
- Installing the expansion card risers
- Removing expansion card from the expansion card riser
- Installing an expansion card into the expansion card riser
- Removing the full length expansion card risers
- Installing the full length expansion card risers
- Removing a GPU
- Installing a GPU
- Removing R1 and R3 paddle cards
- Installing R1 and R3 paddle cards
- Optional serial COM port
- Optional VGA port for liquid cooling module
- Optional IDSDM module
- MicroSD card
- Optional BOSS S2 module
- System battery
- Optional internal USB card
- Intrusion switch module
- Optional OCP card
- Power supply unit
- Trusted Platform Module
- System board
- LOM card and rear I/O board
- Control panel
- Upgrade Kits
- Jumpers and connectors
- System diagnostics and indicator codes
- Getting help
- Documentation resources
• Internal USB card kit
• Serial COM port kit
• VGA port kit
• DPU kit
BOSS S2 module kit
The BOSS S2 module supports up to two M.2 SSDs.
NOTE: To enable the BOSS S2 module in the system, ensure that the BIOS firmware version is 1.5.5 and iDRAC firmware
version is 4.30.30.30 or later.
Before you begin the installation or removal process, follow the safety guidelines and before working inside the system
instructions.
Table 76. BOSS S2 module kit components
R750 (quantity) Components in kit
NA BOSS cover
1 M3 x 0.05 x 4.5 mm screws
1 BOSS signal cable
1 BOSS power cable
1 BOSS-S2 module
1 or 2* BOSS-S2 card carrier
1 or 2* M.2 SSD
2 M.2 240 GB information label
2 M.2 480 GB information label
1 BOSS card filler
1 Tech sheet
To remove the BOSS blank :
1. Power off the system and remove the system cover.
2. Use a screwdriver to push out the blank from the BOSS S2 module bay.
Upgrade Kits
221