User Manual
Table Of Contents
- Dell EMC PowerEdge R750 Installation and Service Manual
- Contents
- About this document
- System overview
- Initial system setup and configuration
- Minimum to POST and system management configuration validation
- Installing and removing system components
- Safety instructions
- Before working inside your system
- After working inside your system
- Recommended tools
- Cable routing
- M.2 SSD module
- Optional front bezel
- System cover
- Drive backplane cover
- Air shroud
- Removing the air shroud
- Installing the air shroud
- Removing the GPU air shroud
- Installing the GPU air shroud
- Removing the GPU air shroud top cover
- Installing the GPU air shroud top cover
- Removing the GPU air shroud filler
- Installing the GPU air shroud filler
- Removing the rear drive module air shroud
- Installing the rear drive module air shroud
- Cooling fans
- Side wall brackets
- Drives
- Rear drive module
- Drive backplane
- PERC module
- System memory
- Processor and heat sink module
- Expansion cards and expansion card risers
- Expansion card installation guidelines
- Removing the expansion card risers
- Installing the expansion card risers
- Removing expansion card from the expansion card riser
- Installing an expansion card into the expansion card riser
- Removing the full length expansion card risers
- Installing the full length expansion card risers
- Removing a GPU
- Installing a GPU
- Removing R1 and R3 paddle cards
- Installing R1 and R3 paddle cards
- Optional serial COM port
- Optional VGA port for liquid cooling module
- Optional IDSDM module
- MicroSD card
- Optional BOSS S2 module
- System battery
- Optional internal USB card
- Intrusion switch module
- Optional OCP card
- Power supply unit
- Trusted Platform Module
- System board
- LOM card and rear I/O board
- Control panel
- Upgrade Kits
- Jumpers and connectors
- System diagnostics and indicator codes
- Getting help
- Documentation resources
NOTE: The procedure to install the liquid cooling rear I/O board and rear I/O boards is same.
Steps
1. Align the connectors and slots on the LOM card or rear I/O board with the connector and standoffs on the system board.
2. Press the LOM card or rear I/O board until firmly seated on the system board connector.
3. Using a Phillips #2 screwdriver, secure the LOM card or rear I/O board to the system board with screws.
Figure 216. Installing the LOM card and rear I/O board
Figure 217. Installing the liquid cooling rear I/O board
Next steps
1. Install the system board.
2. Follow the procedure listed in After working inside your system.