User Manual

Table Of Contents
Table 74. Configuration 9: R2A (continued)
Card type Slot priority Maximum number of cards
Broadcom (NIC: 10Gb, LP) 3 1
Intel (NIC: 10Gb, LP) 3 1
Qlogic (NIC: 10Gb, LP) 3 1
Broadcom (NIC: 1Gb, LP) 3 1
Intel (NIC: 1Gb, LP) 3 1
Mellanox (NIC: HDR100 VPI, LP) 3 1
Mellanox (NIC:HDR VPI, LP) 3 1
Intel (NIC:ACC100, LP) 3 1
Mellanox (OCP: 25Gb) Integrated slot 1
SolarFlare (OCP: 25Gb) Integrated slot 1
Broadcom (OCP: 25Gb) Integrated slot 1
Intel (OCP: 25Gb) Integrated slot 1
QLogic (OCP: 25Gb) Integrated slot 1
Broadcom (OCP: 10Gb) Integrated slot 1
Intel (OCP: 10Gb) Integrated slot 1
QLogic (OCP: 10Gb) Integrated slot 1
Broadcom (OCP: 1Gb) Integrated slot 1
Intel (OCP: 1Gb) Integrated slot 1
Foxconn (External Adapter - HBA355e, H840, FH,
LP)
3 1
Foxconn (External Adapter - HBA355e, H840, LP) 3 1
Dell (External Adapter- H840, FH, LP) 3 1
Inventec (BOSS S1, FH) 3 1
Inventec (BOSS S1, LP) 3 1
Inventec (BOSS S2 Adapter) Integrated slot 1
Removing the expansion card risers
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the air shroud or remove the GPU air shroud.
4.
NOTE:
If BOSS S2 module is installed, ensure to disconnect the BOSS S2 power cable and Signal cable before removing
the Riser 1 cage.
152 Installing and removing system components