Specifications
failover
BIG-IPĀ® Reference Guide 7-9
failover
This group of commands affects the fail-over status of the BIG-IP or 3-DNS
system.
In an active/standby or active-active configuration, run the following
command to place a BIG-IP or 3-DNS system in standby mode:
b failover standby
Show the status of the BIG-IP or 3-DNS system with the following
command:
b failover show
In an active-active configuration, run the following command after you
issue the bigpipe failover standby command. This allows the inactive unit
to resume handling connections:
b failover failback
Note
The failback command is only applicable if you are running a redundant
system in active-active mode.
You can use the bigpipe failover init command to refresh the parameters of
the fail-over mechanism with any new configuration data entered in the
BIG/db database.
b failover init
b failover active | standby | show | init | failback