Delfield ™ ® Specification Line® Installation, Use and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
Delfield Important Warning And Safety Information WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment. WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death. WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other Appliance. WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not Operate This Equipment.
Specification Line Contents Receiving And Inspecting The Equipment.............................3 Serial Number........................................................................4 Warranty Information.............................................................4 Model Numbers.....................................................................5 Introduction...........................................................................6 Specifications.........................................................
Delfield Serial Number Location The serial number is on the identification plate that also includes the model number. On refrigeration and freezer units the identification plate is located inside the left most door near the top front corner of the left interior wall. On heated units, the identification plate is located in the shroud area on the right side panel. Always have the serial number of your unit available when calling for parts or service.
Specification Line S=Specification Line S=Stainless interior & exterior A=Stainless exterior, aluminum interior M=Stainless front, aluminum sides and interior R=Refrigerator F=Freezer H=Heated D=Dual Temp None=Reach-in PT=Pass Thru RI=Roll-in RT=Roll Thru FF=Fish Drawers RL=Refrigerator Left FL=Freezer Left TR=Top Refrigerator BR=Bottom Refrigerator TP=Top Refrigerator Pass Thru BP=Bottom Refrigerator Pass Thru RP=Refrigerator Left Pass Thru FP=Freezer Left Pass Thru 1=1 Section 2=2 Section 3=3 Section
Delfield Introduction Model numbers starting with the letters “SS” have a stainless steel exterior and interior. Model numbers starting with the letters “SA” have an aluminum interior and a stainless steel exterior. Model numbers starting with the letters “SM” have an aluminum interior and exterior with a stainless steel front and shroud. Door gaskets are magnetic and mount to the door, snapping in place and are removable without tools. Keyed door lock is mounted in the door next to the handle.
Specification Line Specifications Reach-In Refrigerators - Hinged Doors - Standard Width & Depth Voltage Amps Volume Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug SSR1-S,SH,G,GH SAR1-S,SH,G,GH SMR1-S,SH,G,GH 115 6.0 24.96 12.81 3 1/4 2092 12.5 418lbs/190kg 5-15P SSR2-S,SH,G,GH SAR2-S,SH,G,GH SMR2-S,SH,G,GH 115 9.5 51.92 27.54 6 1/3 3226 19 650lbs/295kg 5-15P SSR3-S,SH,G,GH SAR3-S,SH,G,GH SMR3-S,SH,G,GH 115 14.5 78.89 42.
Delfield Specifications, continued Reach-In Refrigerator/Freezer Combinations - Dual Temps - Hinged Doors - Standard Width & Depth Model SSDTR1-SH, GH, SSDBR1-SH, GH, SADTR1-SH, GH, SADBR1-SH, GH, SMDTR1-SH, GH, SMDBR1-SH, GH SSDRL2-S,SH, SSDFL2-S,SH, SADRL2-S,SH, SADFL2-S,SH, SMDRL2-S,SH, SMDFL2-S,SH SSDRL2-G,GH SSDFL2-G,GH SADRL2-G,GH SADFL2-G,GH SMDRL2-G,GH SMDFL2-G,GH Section V Amps Volume Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz.
Specification Line Specifications, continued Pass-Thru Hot Food Cabinets - Hinged Doors - Standard Width & Depth Voltage Amps Volume Ft3 Shelf Capacity Ft2 No. Of Shelves Shipping Weight NEMA Plug SSHPT1-S,SH SAHPT1-S,SH SMHPT1-S,SH 120/208-240 9.0 26.96 12.81 3 398lbs/181kg N/A SSHPT2-S,SH SAHPT2-S,SH SMHPT2-S,SH 120/208-240 16.0 51.92 27.54 6 650lbs/295kg N/A Model Reach-In Freezers - Hinged Doors - Standard Width & Depth Voltage Amps Volume Ft3 Shelf Capacity Ft2 No.
Delfield Specifications, continued Pass-Thru Refrigerators - Hinged Doors - Standard Width Voltage Amps Volume Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug SSRPT1-S,SH SARPT1-S,SH SMRPT1-S,SH 115 6.0 26.64 12.81 3 1/4 2092 12.5 455lbs/206kg 5-15P SSRPT1-G,GH SARPT1-G,GH SMRPT1-G,GH 115 7.0 26.64 12.81 3 1/3 2488 12.5 455lbs/206kg 5-15P SSRPT2-S,SH SARPT2-S,SH SMRPT2-S,SH 115 14.5 55.42 27.
Specification Line Specifications, continued Roll-In Refrigerators Voltage Amps Volume Ft3 Shelf Capacity Ft2 No. Of Shelves H.P. BTU/HR R-404A Charge Oz. Shipping Weight NEMA Plug SSRRI1-S SARRI1-S SMRRI1-S 115 6.0 36.15 N/A N/A 1/4 2092 12.5 476lbs/216kg 5-15P SSRRI1-G SARRI1-G SMRRI1-G 115 7.0 36.15 N/A N/A 1/3 2488 12.5 476lbs/216kg 5-15P SSRRI2-S SARRI2-S SMRRI2-S 115 9.5 76.34 N/A N/A 1/3 3226 19 768lbs/348kg 5-15P SSRRI2-G SARRI2-G SMRRI2-G 115 14.5 76.
Delfield Specifications, continued Hot Food Roll-Ins Voltage Amps Volume Ft3 Shelf Capacity Ft2 No. Of Shelves Shipping Weight NEMA Plug SSHRI1-S,G SAHRI1-S,G SMHRI1-S,G 120/208-240 9.0 36.15 N/A N/A 459lbs/ 208kg N/A SSHRI2-S, G SAHRI2-S, G SMHRI2-S, G 120/208-240 16.0 76.34 N/A N/A 704lbs/ 319kg N/A SSHRI3-S, G 120/208-240 17.8 113.28 N/A N/A 1008lbs/457kg N/A Model Roll-Thru Refrigerators - Hinged Doors Voltage Amps Volume Ft3 Shelf Capacity Ft2 No. Of Shelves H.P.
Specification Line Installation Location Stabilizing Cabinets represented in this manual are intended for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet, 1000 pounds. per door section. Reinforce the floor if necessary to provide for maximum loading. For the most efficient operation, be sure to provide good air circulation inside and out. The location should be selected so that the power cord can be connected without any extensions.
Delfield Installation, continued Electrical Connection Refer to the amperage data list in the SPECIFICATIONS or the serial tag data and your local code or the National Electrical Code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for connection of the supply cord or permanent connection to the unit. The power must be turned off and disconnected whenever performing maintenance or repair functions.
Specification Line Heated Cabinet Operation The Heated units have a POWER ON/OFF switch located behind the flip up shroud at the front top of the unit for controlling power to the unit and an electronic thermostat for setting the temperature. A circulating fan provides uniform airflow in the cabinet. Power Up 1. 2. 3. 4. 5. 6. Check that unit is properly connected to the power source. Raise the shroud to access the controls. Set the Main POWER ON/OFF switch, to the ON position.
Delfield Electronic Temperature Control Operation These instructions are applicable to most models, The electronic temperature control constantly monitors box temperature as well as evaporator coil temperature to maintain consistent product temperatures. The control also sends temperature readings to the digital temperature display. The control circuits continually self-check and if an error occurs, the digital display will switch from temperature read-out to error read-out, i.e. E1.
Specification Line Electronic Temperature Control Operation, continued Freezer Automatic Defrost The control also monitors compressor total running time and will enter a defrost cycle after total compressor running time is greater than 4-hours since the last defrost cycle OR if evaporator coil temperature drops below -30ºF (-34ºC) (indicating excessive frost on the coil.
Delfield Door Reversal Procedures Only for Models Ordered With Re-Hinging Option. The re-hinging option is only available on solid door models. 1. Lift front shroud if re-hinging the control side. If re-hinging the rear side, the shroud must be removed. 2. Open door 90˚ and lift door straight up and off hinges. 3. Remove the metal screw covers on each door-side hinge section by sliding it down and off. 4.
Specification Line Maintenance Door Gasket Maintenance Door gaskets require regular cleaning to prevent mold and mildew build up and also to retain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid full strength cleaning products on gaskets as this can cause them to become brittle and crack. Never use sharp tools or knives to scrape or clean the gasket. Gaskets can be easily replaced and do not require the use of tools or an authorized service person.
Delfield Maintenance, continued and preserve the finish of the steels protective layer. Early signs of stainless steel breakdown are small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel. Never use an acid based cleaning solution! Many food products have an acidic content, which can deteriorate the finish. Be sure to clean the stainless steel surfaces of ALL food products.
Specification Line REVISIONS REV Wiring Diagram Specification Line Refrigerators DATE APPROVED 1 INITIAL RELEASE DESCRIPTION 2 ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL 17-MAY-2011 L ENNIS 3 BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY) 26-MAY-2011 L ENNIS 11" S_RRT1, SSRFF1 - Solid Doors S_R1, S_R1N, S_R1S, S_RPT1, S_RPT1S, S_RRI1, 9294455 L1 NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED N LINE VOLTAG
Delfield REVISIONS REV Wiring Diagram Specification Line Refrigerators DATE APPROVED 1 INITIAL RELEASE DESCRIPTION 2 ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL 17-MAY-2011 L ENNIS 3 BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY) 26-MAY-2011 L ENNIS 11" S_R2, S_R2N, S_R2S, S_R2-SL, S_R2S-SL, S_RPT2S, S_RRI2, SSRFF2 - Solid Doors 9294454 L1 NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED N LINE VOLTAGE 115/
Specification Line Wiring Diagram Specification Line Refrigerators S_RPT2, S_RRT2, S_R3, S_RRI3 - Solid Doors 9294479 L1 POWER SWITCH NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED N LINE VOLTAGE 115/60/1 SEE NAMEPLATE FOR MAXIMUM FUSE SIZE EVAPORATOR HOUSING EVAP FAN MOTOR M TEMPERATURE CONTROL Y N 5 BLUE F M 6 FAN RELAY PLUG W EVAP COIL SENSOR CONTROL CIRCUIT CABINET AIR SENSOR L 2/3 EVAPORATOR FAN INCANDESCENT
Delfield Wiring Diagram Specification Line Freezers S_F1, S_F1N, S_F1S - Solid Doors S_F1 - Glass Doors 24
Specification Line Wiring Diagram Specification Line Freezers S_FPT1, S_FRI1 - Solid Doors 9294108 L1 NOTES: 1) USE COPPER CONDUCTORS ONLY 2) THIS UNIT MUST BE GROUNDED 3) UNIT SHOWN WITH COMPRESSOR RUNNING AND DOORS CLOSED N LINE VOLTAGE 115/60/1 SEE NAMEPLATE FOR MAXIMUM FUSE SIZE POWER SWITCH Y N BLUE F M 6 PLUG DEFROST HEATER EVAP COIL SENSOR 5 FAN RELAY HIGH TEMP LIMIT SWITCH M TEMPERATURE CONTROL CONTROL CIRCUIT 3 EVAP FAN MOTOR CABINET AIR SENSOR L EVAPORATOR HOUSING EVAPORATO
Delfield Wiring Diagram Specification Line Freezers S_F2 - Glass Doors S_FRI2, S_F3 - Solid Doors 26
Specification Line Wiring Diagram Specification Line Refrigerator/Freezer Combinations S_DTR1, S_DBR1 - Solid & Glass Doors L1 L 3 DOOR SWITCH TEMPERATURE CONTROL CONTROL CIRCUIT DOOR SWITCH HI-LIMIT N 5 F 6 H 4 C 1 N 5 F 6 H 4 C 1 CONDENSATE HEATER M EVAPORATOR FAN M COMPRESSOR M CONDENSOR FAN M EVAPORATOR FAN DEFROST HEATER M COMPRESSOR M CONDENSOR FAN DOOR FRAME HEATER (REF & FRZ) INCANDESCENT LIGHT DRAIN HEATER HI-PRESSURE SWITCH HI-LIMIT INCANDESCENT LIGHT HI-PRESSURE SWITCH
Delfield Wiring Diagram Specification Line Heated Models S_H1, S_H2, S_HRI1, S_HRI2 - Solid & Glass Doors S_H2N, S_HPT1, S_HPT2, S_HRT1, S_HRT2 - Solid Doors S_H3, SSHRI3 - Solid & Glass Doors S_HRT3 - Solid Doors 28
Specification Line Compressor Diagrams Capacitor, start Relay & Overload Valve, EXP Compressor Drier, filter Motor, fan, evaporator Motor, fan, condensor Blade, fan Guard, fan, condenser Coil, condenser Coil, evaporator Fan delay, defrost limit Blade, fan, condenser Guard, fan, condenser Coil, evaporator Coil, condenser Valve, EXP Motor, fan, evaporator Compressor Relay & Overload Blade, fan Capacitor, start Fan delay, defrost limit Heater, defrost Switch Control switch Drier, filter 29
Delfield Replacement Parts S_R1, S_R1N, S_R1S, S_RPT1, S_RPT1S, SSRFF1, S_RRI1, S_DRL2, S_DFL2, S_DRP2, S_DFP2 - Solid Doors S_R1, S_R1N, S_R1S, S_DRL2, S_DFL2 - Glass Doors S_R2S, S_R2S-SL, S_RRT1 - Solid Doors S_R2S, S_R2S-SL, S_RPT1, S_RRI1 - Glass Doors Part Number Description Part Number Description 2194792 Display, Blue, Danfoss 2194792 Display, Blue, Danfoss 3516433 Blade, Fan, 25 3516432 Blade, Fan, 25Deg, 8.75" 3517390 Blade, Fan, 5.56, CW, Lexan 3517390 Blade, Fan, 5.
Specification Line Replacement Parts, continued S_F1, S_F1N, S_F1S, S_DRL2, S_DFL2 - Solid Doors S_DRL2, S_DFL2 - Glass Doors S_FPT1, S_FRI1, S_F2S, S_DRP2, S_DFP2 - Solid Doors S_F1 - Glass Doors Part Number Description Part Number Description 3516432 Blade, Fan, 25DEG, 8.75" 3516433 Blade, Fan, 25 3517390 Blade, Fan, 5.56, CW, Lexan 3517390 Blade, Fan, 5.
Delfield Shelf Replacement Parts S_DTR1, S_DBR1 - Solid & Glass Doors Model Shelf Number Part Number Description S_R1-S, SH, G, GH 3978170 3516172 Blade, Fan, 5.56, CCW S_R2-S, SH, G, GH 3516432 Blade, Fan, 25deg, 8.75", Cw S_RPT1-S, SH, G, GH 3516427 Coil, Condenser, Large, Upright S_DTR1-SH, GH 3516239 Coil, Evap, Refrig., RT, Spec S_DBR1-SH, GH 3516220 Coil, Evap, Frz, RT, Spec 3526999 Compressor, Frz., Nf5.
Specification Line Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
Delfield Notes 34
Specification Line Notes 35
Delfield ™ Mt. Pleasant, MI ® Covington, TN Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:________________________ S/N: _______________________ Installation Date:________________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com Register your Delfield warranty online. Go to www.