Drop Ins N8000, N8000-R, N8100B, N8100-BR, 8100-EF, N8100-FA, N8200, N8200-ST, N8200G, N8600, N8700-D, N8700-DESP, N8700-R, N8800 Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
N8000 Series Drop-In Installation and Operation Manual Important Warning And Safety Information WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment. WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death. WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other Appliance.
N8000 Series Drop-In Installation and Operation Manual Contents Receiving And Inspecting Unit................................................. 3 Serial Number Location........................................................... 4 Warranty Information............................................................... 4 Regulatory Certifications......................................................... 4 Specifications.......................................................................
N8000 Series Drop-In Installation and Operation Manual Serial Number Location The serial number on self-contained refrigerated units is on the electrical specifications tag located near the condensing unit. The serial number on remote refrigerated units is on the outside bottom of the food well. On hot food pans and hot/cold combination pans, the serial number tag is located on the back of the control raceway or remote panel. The serial number tag also lists the refrigerant used and the amount of charge.
N8000 Series Drop-In Installation and Operation Manual Specifications N8100B Series Self-Contained Mechanically Cooled Pans - R134A Model L D H Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU Evap BTU/ TD/TEMP Sys Cap Ship Weight Refrig. Charge NEMA Plug 12”x20” Pans N8118B 18” (45.7cm) 26” (66cm) 21.87” (55.5cm) 17” X 25” (43.2cm x 63.5cm) 115/60/1 4.0 1/5 204 19/38º/-3º 708 100lbs (45kg) 8.0oz 5-15P 1 N8130B 30.75” (78.1cm) 26” (66cm) 21.87” (55.5cm) 29.75” x 25” (75.
N8000 Series Drop-In Installation and Operation Manual Specifications 8100-EF Series LiquiTec® Eutetic Fluid Refrigerated Cold Pans - R404A Model L D H Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU Load Evap BTU/ TD/TEMP Sys Cap Ship Weight Refrig. Charge NEMA Plug 12x20 Pans 8118-EF 18.20” (46.2cm) 26” (66cm) 23.25” (59.1cm) 17” x 25” (43.2cm x 63.5cm) 115/60/1 7.5 1/4 204 19/50º/-15° 928 169lbs (77kg) 24.0oz 5-15P 1 8132-EF 31.76” (80.7cm) 26” (66cm) 23.25” (59.
N8000 Series Drop-In Installation and Operation Manual Specifications N8000-R Series Curved Ice Cooled Cold Pans Model Counter Cutout Dimensions Ship Weight 12”x20” Pans Held see drawing on page 10 100lbs (45kg) 2 10.77” (27cm) see drawing on page 10 118lbs (53kg) 3 26.05” (66cm) 10.77” (27cm) see drawing on page 10 145lbs (65kg) 4 26.05” (66cm) 10.77” (27cm) see drawing on page 10 164lbs (74kg) 5 L 40.48” (103cm) D 26.05” (66cm) H 10.77” (27cm) N8059-R 57.22” (145cm) 26.
N8000 Series Drop-In Installation and Operation Manual Specifications N8600 Series Self Contained Combination Hot/Cold Food Wells - R404A V/Hz/Ph Amps H.P. BTU Evap BTU/ TD Sys Cap Ship Weight Refrig. Charge 12.25” x 4.25” x 7.00” (31.1cm x 10.8cm x 17.8cm) 120/60/1 25.0 1/4 379 26/42º/-7° 1112 164lbs (74kg) 16.0oz 2 42.50” x 25” (107.9cm x 63.5cm) 12.25” x 4.25” x 7.00” (31.1cm x 10.8cm x 17.8cm) 120/240 /60/1 21.0 1/4 569 35/36º/-1° 1259 198lbs (90kg) 16.0oz 3 23.75” (60.
N8000 Series Drop-In Installation and Operation Manual Specifications N8700-R Series Curved Individually Controlled Heated Food Wells Model Counter Cutout Dimensions 12”x20” Pans 16.6 99lbs (45kg) 2 208-230 /60/1 15.0/16.0 134lbs (61kg) 3 18.69” x 4.62” x 7.00” (47cm x 12cm x 18cm) 208-230 /60/1 20.0/22.0 166lbs (75kg) 4 22.88” x 4.62” x 7.00” (58cm x 12cm x 18cm) 208-230 /60/1 24.0/27.
N8000 Series Drop-In Installation and Operation Manual Curved Drop-In Cutout Details 2 pan standard curved drop-in cutout detail Models: 19.75” • N8044-R 50cm • N8144-BR • N8744-R 19.75” 50cm 172.50˚ 85˚ 2-PAN STD. RADIAL DROP-IN CUTOUT DETAIL 25.00” 64cm 25.00” 64cm 25.10” 64cm 85˚ 25.10” 64cm 95˚ 95˚ 172.50˚ 15.92” 40cm 15.92” 40cm 3 pan standard curved drop-in cutout detail Models: 19.56” • N8059-R 50cm • N8159-BR • N8759-R 17.06” 43cm 3-PAN STD. RADIAL DROP-IN CUTOUT DETAIL 25.
N8000 Series Drop-In Installation and Operation Manual Installation N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200, N8200-ST, N8200G, N8100-FA & 8100-EF These units are intended for indoor use only. A room temperature of no more than 86°F (30°C) is recommended. Be sure the location chosen has a counter strong enough to support the total weight of the unit and contents. A fully loaded model may weigh as much as 600 pounds! Reinforce the counter as necessary to provide maximum loading.
N8000 Series Drop-In Installation and Operation Manual Installation N8700-D, N8700-DESP, N8700N, N8700-R & N8800 Series These units are intended for indoor use only. Be sure the location chosen has a counter strong enough to support the total weight of the unit and contents. A fully loaded model may weigh as much as 600 pounds! Reinforce the counter as necessary to provide maximum loading. Plumbing N8700-D, N8700-DESP, N8700N-D and N8700-R Plumbing: Unit is equipped with 1/2” (1.
N8000 Series Drop-In Installation and Operation Manual Operation All Cold Pan Models These units are not designed to cool warm food products. Items should be placed in the unit pre-cooled at least to the desired holding temperature, if not slightly colder. In some applications, a gradual warming of product may occur, particularly at the exposed top of the product. Stirring or rotation of the product may be necessary to maintain overall temperature.
N8000 Series Drop-In Installation and Operation Manual Operation 8100-EF Series There is a switch on the compressor housing front to turn the 8100-EF units on and off. 8100-EF Series LiquiTec® Eutetic fluid cold pans are adjusted at the factory to provide proper operation without any further adjustments. However, if it is necessary to adjust the temperature, the control is located in the machine compartment. Turn the knob clockwise as indicated on the control to adjust it colder.
N8000 Series Drop-In Installation and Operation Manual Operation N8600 Hot/Cold Series Hot Operation N8600 Series hot and cold combination pans must be operated with water in the well for proper hot operation. Fill well with a minimum of 4” (10.2cm) of water. Place function switch in HOT position to begin heating. Turn thermostat dial to the desired temperature. Never use anything other than plain water in the wells or tank.
N8000 Series Drop-In Installation and Operation Manual Operation N8700-D, N8700N, N8700-R & N8800 Series These units are designed to hold warm food product between 140 F to 160 F (60 C to 71 C). N8700-D, N8700N and N8700-R series individually heated hot food units may be operated “wet” (with water in the wells) or “dry”. However, “wet” operation is recommended for better performance. Wet Operation Fill the food well with a minimum of 2” (5.1cm) of water and cover with lid or empty pan.
N8000 Series Drop-In Installation and Operation Manual Operation N8700-DESP Series These units are designed to hold warm food product between 140 F to 160 F (60 C to 71 C). N8700-DESP series individually heated hot food units may be operated “wet” (with water in the wells) or “dry”. However, “dry” operation using 4” deep pans produces optimum performance. A power switch and digital control are provided for each individual heated food well.
N8000 Series Drop-In Installation and Operation Manual Maintenance CAUTION Never hose down interior or exterior of units with water. This will void the warranty. Wipe interior dry of any water accumulation. Drain Maintenance - N8100-FA Series Each unit has a drain located inside the unit that removes the condensation from the evaporator coil and routes it to an external condensate evaporator pan. Each drain can become loose or disconnected during normal use.
N8000 Series Drop-In Installation and Operation Manual Unit Assembly N8100-FA Black Airflow Extrusions Upright Air Diffuser With Air Deflector Perforated Pan Clip Adapter Bars Coil Assy Cover Plexiglas End Caps Wiring Diagram N8100-FA MODELS - NORDIC BREEZE L1 N 1 2 5 G 3 PRESSURE CONTROL CONDENSING UNIT DEFROST TIMER COOLING FANS M:\RFBACKUP\DRAWINGS\NORDICWD.DWG For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8100B, N8100NB & N8100-BR CONDENSER FAN S C L1 COOLING T'STAT R COMPRESSOR 115V N G Wiring Diagram 8100-EF, 8100-EFN CONDENSER FAN S C ON/OFF SWITCH L1 COOLING T'STAT R COMPRESSOR 120V N G Wiring Diagram N8200, N8200-ST & N8200G ON/OFF SWITCH L1 CONDENSER FAN S C R COMPRESSOR 115V N G 20 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8630 Wiring Diagram N8643 & N8656 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8669 & N8681 Wiring Diagram N8800 208/230V LI THERMOSTAT 22 G L2 DOUBLE POLE THERMOSTAT ON MODELS N8873 & N8887 ONLY For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8700-D, N8700N & N8700-R PILOT LIGHT (FURNISHED) H1 1000 W - 120V OR 1000/1222 W 208-230 V HEATING ELEMENT P L1 L2 H2 LINE WIRES TO ADDITIONAL FOOD WARMERS INFINITE CONTROL WITH “OFF” POSITION AMPERES IN LINE WIRES # OF WARMERS 1 120V, 1 PHASE 8.3 2 3 4 208V, 1 PHASE 4.8 230V, 1 PHASE 5.3 16.7 9.6 10.6 25 33.3 14.4 19.2 15.9 21.3 14.4/15.9 14.4/15.9 14.4/15.9 19.2/21.3 19.2/21.3 14.4/15.9 5 24 26.6 19.2/21.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8700-DESP N8700-DESP Technical Service Notes The temperature probes are mounted directly to the heat pad and can only be tested with a meter that can read type J thermocouples. When testing the probe read the temperature of the hot food well. When replacing the well not to apply pressure directly to the pad. Heater Resistance: 208 Volt Heaters Min 82.65 ~ Max 91.35 240 Volt Heaters Min 109.20 ~ Max 120.
N8000 Series Drop-In Installation and Operation Manual Miscellaneous Parts 8000 SERIES Delfield Part # Description Cap Tube Chart - R134A Refrigerant 265-AXE-0000 Divider bar, 2.00” x 20.93” Model Number Cap Tube Size/Length 243-ALS-0032 Divider bar, 13.00” x .90” N8118B .036ID x 72” 243-AB0-0001 Divider bar, 21.00” x .90” N8130B .036ID x 72” 3234242 Plastic drain N8143B .036ID x 72” 1701273 Trim gasket (sold by foot) N8144-BR .
N8000 Series Drop-In Installation and Operation Manual Replacement Parts N8100-FA 8 7 9 6 1 2 5 3 10 4 11 12 13 14 15 16 17 Delfield Part # Per Model Key Description N8131-FA 2-PAN N8144-FA 3-PAN N8157-FA 4-PAN N8169-FA 5-PAN N8182-FA 6-PAN 1 Upright diffuser 226-0V3-0030 226-0V3-0031 226-0V3-0032 226-0V3-0033 226-0V3-0034 2 Air deflector 226-A9L-0030 226-A9L-0031 226-A9L-0032 226-A9L-0033 226-A9L-0034 3 Coil 3510086 3510086 3510086 3510086 3510086 4 Expansion valve
N8000 Series Drop-In Installation and Operation Manual Narrow Base Condensing Unit Assembly 1/5 H.P. R134A, Low N8118B, N8130B, N8143B, N8144-BR, N8146NB, N8168NB 1 Key Delfield Part # Description 1 2183300 Harness, wire, power cord, 8100 2 3526694 Compressor, 1/5 h.p.,115v/60hz 3526718 Compressor, 1/5 h.p., 220v/50hz 3 3516047 Cold Control 4 024-ADB-0040 Compressor stand 5 031-264-0000 Bracket, fan motor, blower coil 6 3516172 Blade, fan, 5.
N8000 Series Drop-In Installation and Operation Manual Narrow Base Condensing Unit Assembly N8156B, N8159-BR, N8169B, N8176-BR, N8181B, N8194-BR Key Delfield Part # Description 1 2183300 Harness, wire, power cord 2 3526703 Compressor, 1/3HP, 115/60, R134A, N8181B, N8194-BR 3526695 Compressor, 1/4 h.p.,115v/60hz, N8156B, N8159-BR, N8169B, N8176-BR 3526719 Compressor, 1/4 h.p.
N8000 Series Drop-In Installation and Operation Manual Condensing Unit Assembly 1/2 H.P. R404a, Low, N8273G Key Delfield Part # Description - 000-BN5-0033 Condensing Unit Assembly, 115V - 000-BN5-003N Condensing Unit Assembly, 220V/50Hz 1 026-C58-0031 Shroud, 1/2 HP Condenser Coil 2 3516554 Blade, Fan, 9.00”, 5-pedal 3 2160019 Guard, Fan, Condenser, Upright 4 2162716 Motor, Fan, 16W, 115V 2162721 Motor, Fan 16W, 230V 5 3516324 High Pressure Switch 6 3527001 Compressor, SC12CLX.
N8000 Series Drop-In Installation and Operation Manual Condensing Unit Assembly 3/4 H.P. N8169-FA, N8182-FA Key Delfield Part # Description - 000-BN5-0036 Condensing Unit Assembly 1 026-C58-0032 Shroud, 3/4 HP condenser coil 2 2160019 Guard, fan, condenser, upright 3 3516442 Capacitor, start, run, assembly 4 3527021 Compressor, SC18MLX, 115V/60Hz, Danfoss 5 3516322 Filter dryer, (2) inlet, .
N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Thermostat control N8600 For models N8600 1 10 Key 9 2 8 7 6 5 4 Delfield Part # Description 1 2194075 Immersion heater 120V, 1Ph 1 2193974 Immersion heater 240V 1Ph 5KW 2 026-AO6-0041 Box, control, galv, 8600 series 3 372-ANQ-003D Front, collar, mounting, 8600 4 2193979 Switch, 3 position, 30Amp 5 372-ANS-0001 Cover, control box, 8700 series 6 2194190 Light, pilot, 125V, red 7 2194202 Thermo
N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Thermostat Control N8800 For models N8831, N8859, N8873, N8887 Key Delfield Part # Description 1 3234556 Knob, thermostat control 2 2193984 Thermostat 30A, N8873.
N8000 Series Drop-In Installation and Operation Manual Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. A maximum of 1-hour is allowed to diagnose a defective component. A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed. Actual travel to be charged.
N8000 Series Drop-In Installation and Operation Manual Notes 34 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Notes For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
Covington, TN Mt. Pleasant, MI Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:_____________________ S/N: ____________________ Installation Date:_____________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com Register your Delfield warranty online. Go to www.delfield.