Installation manual
International F5 & F15 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
8
1.75"
4cm
1.00"
2.5cm
C
Front Of Unit
J= Junction Box
R= Refrigeration Lines,
 0.25" Liquid,
 0.37" Suction
D= 0.50" I.D. Drain
R
D
D
J
3.75"
10cm
30.00"
76cm
3.75"
10cm
Typical Mechanical Access (Plan View)
All F15 Models
Installation: Remote F15 Series
Location
Units represented in this manual are for indoor use only. Be 
sure the location chosen has a floor strong enough to support 
the total weight of the cabinet and contents. A fully loaded model 
may weigh as much as 3,000 pounds! Reinforce the floor as 
necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good air 
circulation inside and out. Don’t pack the refrigerator so full 
that air cannot circulate. Be sure that the exterior of the unit has 
access to ample air. Avoid hot corners and locations near stoves 
and ovens.
Unit is designed to maintain 36°F (2°C) to 40°F (4°C) interior 
cabinet temperature at 55% or lower ambient relative humidity.
Leveling
A level cabinet looks better and will perform better because 
the drain pan will drain properly, the doors will line up with 
the frames properly and the cabinet will not be subject to 
undue strain. Units come standard with adjustable legs and 
bullet feet to make leveling easier. If your unit has casters, 
install in a stable condition with the front casters locked before 
operating.
Plumbing
Self-contained models are standard with a condensate 
evaporator. If your unit does not have a condensate evap o ra tor, 
or the evaporator fails, the unit’s drain must have an outlet to an 
appropriate drainage area or container.
Moisture collecting from improper drainage can 
create a slippery surface on the floor and a hazard 
to employees. It is the owner’s responsibility to 
provide a container or outlet for drainage.
Electrical connection
Refer to the amperage data on the specification pages, the serial 
tag, your local code or the National Electrical Code to be sure the 
unit is connected to the proper power source. A protected circuit 
of the correct voltage and amperage must be run for con nec tion 
of the line cord, or permanent connection to the unit.
Self-contained units have an ON/OFF switch located directly 
behind the louvered panel covering the compressor section. 
Simply turn the switch to ON to begin operation.
The power switch should be turned to OFF  and 
the unit disconnected from the power source 
whenever performing service or maintenance 
functions.
CAUTION
Installation: Self-Contained F15 Series