Installation manual
International F5 & F15 Series Service and Installation Manual
7
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
Location
Units represented in this manual are for indoor use only. All 
self-contained units were tested at the factory to assure proper 
operation. The unit should not be installed directly next to high 
heat generating equipment (ranges, griddles, etc.). Be sure the 
location chosen has a counter strong enough to support the 
total weight of the cabinet and contents. A fully loaded model 
may weigh as much as 2,000 pounds! Reinforce the counter as 
necessary to provide for maximum loading.
These units are installed by “dropping” them into the counter 
from above. The counter cutout sizes are as follows:
48” wide units — 18.62" x 23.62" (47.3 cm x 60.0 cm)
72” wide units — 18.62" x 32.62" (47.3 cm x 82.9 cm)
Self-contained F5 Series units require airflow to the 
compressor. Two louvers are provided with each unit and 
should be installed as illustrated on page 13.
Unit is designed to maintain 36°F (2°C) to 40°F (4°C) interior 
cabinet temperature at 55% or lower ambient relative humidity.
Plumbing
Self-contained models are standard with a condensate 
evaporator. If, for some reason, a unit does not have a 
condensate evaporator, or the evaporator fails, the unit’s 
drain must have an outlet to an appropriate drainage area or 
container.
Moisture collecting from improper drainage 
can create a slippery surface on the floor 
and a hazard to employees. It is the owner’s 
responsibility to provide a container or outlet 
for drainage.
Electrical connection
Refer to the amperage data on the specification pages, the 
serial tag, your local code or the National Electrical Code to 
be sure the unit is connected to the proper power source. A 
protected circuit of the correct voltage and amperage must be 
run for con nec tion of the line cord, or permanent connection 
to the unit.
Self-contained units have an ON/OFF switch in the junction 
box. Simply turn the switch to ON to begin operation.
The power switch should be turned to OFF and 
the unit disconnected from the power source 
whenever performing service or maintenance 
functions.
CAUTION
Installation: Self-Contained F5 Series
1.75"
(4cm)
C
Cutout
3.00" X 12.00" (8cm X 30cm)
Centered Front To Back 
0.25" (0.6cm) From End
Front Of Unit
J= Junction Box
R= Refrigeration Lines,
 0.25" Liquid,
 0.37" Suction
D= 0.50" I.D. Drain
R
D
J
3.75"
(10cm)
3.75"
(10cm)
Typical Mechanical Access (Plan View)
All F5 Models
Installation: Remote F5 Series