Installation manual
F5 & F15 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
8
Delfield
™
®
Low pressure cut in at 20 psi.
Low pressure cut out at 5 psi.
Differential setting of 15 psi.
Pressure Control Settings
Display Temperature Control Settings
The display temperature control is located on the evaporator
assembly on the ceiling of the display case. It is field
adjustable and does not require a service agent. The factory
setting is 2.5. Set toward 1 for higher temperatures and
toward 7 for lower temperatures.
Please make small incremental adjustments if
a temperature adjustment is necessary. Contact
the service department at Delfield +1 (989) 773-
7981 or your local service agent for additional
assistance. Delfield is not responsible for
charges incurred while adjusting the thermostat.
Base Temperature Control Settings
The base temperature control is located in the machine
compartment. It is field adjustable and does not require a
service agent. The factory setting is 2.5. Set toward 1 for
higher temperatures and toward 7 for lower temperatures.
Please make small incremental adjustments if
a temperature adjustment is necessary. Contact
the service department at Delfield +1 (989) 773-
7981 or your local service agent for additional
assistance. Delfield is not responsible for
charges incurred while adjusting the thermostat.