N8000, N8100B, N8100-FA, 8100-EF, N8200, N8200G, N8600, N8700-D, N8800 Drop Ins Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2.
N8000 Series Drop-In Installation and Operation Manual Contents RECEIVING AND INSPECTING UNIT................................... 2 MECHANICAL DATA.......................................................... 3-5 INSTALLATION N8000, N8000N, N8100B, N8100NB, N8200, N8200G, 8100-FA, 8100-EF Series..................................................... 6 N8700D, N8700N, & N8800 Series...................................... 6 N8600 Series........................................................................
N8000 Series Drop-In Installation and Operation Manual N8000 N8000Series SeriesIce IceCooled CooledCold ColdPans Pans MODEL NUMBER L D H counter CUTOUT DIMENSIONS (D x L) # OF 12” X 20” PANS HELD SHIPPING WEIGHT N8018 18” (45.7cm) 26” (66cm) 10.75 (27.3cm) 17” x 25” 1 (43.2cm x 63.5cm) 37 lbs (17 kg) N8030 30.75” (78.1cm) 26” (66cm) 10.75 (27.3cm) 29.75” x 25” 2 (75.6cm x 63.5cm) 100 lbs (45 kg) N8043 43.5” (110.5cm) 26” (66cm) 10.75 (27.3cm) 42.50” x 25” 3 (107.
N8000 Series Drop-In Installation and Operation Manual N8100-FA Series Air Curtain Cold Pans-R404A MODEL NUMBER COUNTER CUTOUT DIMENSIONS LOUVER CUTOUT DIMENSIONS VOLTZ/HERTZ PHASE SHIP WEIGHT H.P. AMP BTU REFRIG. CHARGE N8131-FA 30.2” x 25.5” 22” (55.8cm) x 11” (27.9cm) 115/60/1 165 N8144-FA 42.95” x 25.5” 22” (55.8cm) x 11” (27.9cm) 115/60/1 175 1/4 8.0 2154 16.0 oz. 1/2 10.0 3142 32.0 oz. N8157-FA 55.7” x 25.5” 22” (55.8cm) x 11” (27.9cm) 115/60/1 N8169-FA 68.45” x 25.
N8000 Series Drop-In Installation and Operation Manual N8700D Series Individually Controlled Electric Hot Food Wells MODEL NUMBER L D H N8717-D 17.88” (45.4cm) 26.00 (66cm) 9.5” (24cm)* N8731-D 31.75” (80.6cm) 26.00 (66cm) 9.5” (24cm)* N8745-D 45.63” (115.9cm) 26.00 (66cm) 9.5” (24cm)* N8759-D 59.5” (151.1cm) 26.00 (66cm) 9.5” (24cm)* N8773-D 73.38” (186.4cm) 26.00 (66cm) 9.5” (24cm)* N8787-D 87.25” (221.4cm) 26.00 (66cm) 9.
N8000 Series Drop-In Installation and Operation Manual Installation N8000, N8000N, N8100B, N8100NB, N8200, N8200G, N8100-FA & 8100-EF Series Drop In Procedure These units are intended for indoor use only. A room temperature of not more than 86°F (30°C) is recommended. Reinforce the counter as necessary to provide maximum loading. CAUTION Some N8000, N8000N, N8100B and N8100NB may have poyethylene insulation in the drain hole.
N8000 Series Drop-In Installation and Operation Manual Installation N8600 Drop In Procedure These units are intended for indoor use only. A room temperature of not more than 86°F (30°C) is recommended. Reinforce the counter as necessary to provide for maximum loading. Unit requires that the sides and bottom are not any closer than 3” to any combustible material. DANGER The counter cut-out sizes and power requirements are shown on pages 3-5. A gasket is installed in the flange of each unit.
AND #40 ." 3ERIES 3ERVICE AND )NSTALLATION -ANUAL 2%&2)'%2!.4 #(!2'%3 !.$ 02%3352% #/.42/, 3%44).
2EFRIGERANT #HARGES &OR 3ERIES 5NITS 04" OZ "5# OZ Manual 04" OZ N8000 Series Drop-In "5# Installation and Operation OZ 04" N8700N & N8800 Series OZ "5# OZ Operation N8700D, 04"
N8000 Series Drop-In Installation and Operation Manual Operation N8600 Hot/Cold Series Hot Operation To assure maximum compressor life, do not switch from “hot” to “cold” operation without allowing a cool down period. Never switch from hot to cold operation while hot water remains in the pans. Failure to observe this warning will greatly reduce compressor life and eventually cause premature compressor failure.
N8000 Series Drop-In Installation and Operation Manual UNIT ASSEMBLY- N8100-FA UPRIGHT AIR DIFFUSER WITH AIR DEFLECTOR BLACK AIRFLOW EXTRUSIONS PERFORATED PAN CLIP ADAPTER BARS COIL ASSY COVER PLEXIGLAS END CAPS wiring diagram 115V N8100FA -/$%,3 ./2$)# "2%%:% , . ' 02%3352% #/.42/, #/.$%.3).' 5.)4 $%&2/34 4)-%2 #//,).' &!.3 - <2&"!#+50<$2!7).'3<./2$)#7$ $7' For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram - N8100B, N8100NB, N8200 & N8200G N8100B Series-115V CONDENSER FAN S C L1 R COMPRESSOR 115V COOLING T'STAT N G N8200 & N8200G Series- 115V CONDENSER FAN S C ON/OFF SWITCH L1 R COMPRESSOR 115V N G Wiring Diagram - N8800 - 208/230V LI THERMOSTAT 12 G L2 DOUBLE POLE THERMOSTAT ON MODELS N8873 & N8887 ONLY For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram - N8700-D & N8700N PILOT LIGHT (FURNISHED) H1 1000 W - 120V OR 1000/1222 W 208-230 V HEATING ELEMENT P L1 L2 H2 LINE WIRES TO ADDITIONAL FOOD WARMERS INFINITE CONTROL WITH “OFF” POSITION AMPERES IN LINE WIRES # OF WARMERS 1 120V, 1 PHASE 8.3 2 3 4 4.8 230V, 1 PHASE 5.3 16.7 9.6 10.6 25 33.3 14.4 19.2 15.9 21.3 14.4/15.9 14.4/15.9 14.4/15.9 19.2/21.3 19.2/21.3 14.4/15.9 5 24 26.6 28.8 31.3 19.2/21.3 28.8/31.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram - N8600 L1 G WIRING FOR N8600 SERIES 120/208V OR 120/240V MODELS WITH ONE OR TWO HEATERS R-404A CAP TUBE REFRIGERATION SYSTEM N L2 CONDENSER FAN FUNCTION SWITCH C COLD OFF HOT S R COMPRESSOR 120V COOLING T' STAT HEATER 1 HEATING T' STAT HEATER 2 PILOT LIGHT Wiring Diagram - N8600 - REMOTE WIRING FOR N8600 SERIES 120/280V OR 120/240V MODELS WITH ONE OR TWO HEATERS REMOTE REFRIGERATION SYSTEM FUNCTION SWITCH COLD OFF HOT C
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram - N8600 120V L1 G WIRING FOR N8600 SERIES 120V MODELS WITH ONE OR TWO HEATERS R-404A CAP TUBE REFRIGERATION SYSTEM N CONDENSER FAN FUNCTION SWITCH C COLD OFF HOT S R COMPRESSOR 120V COOLING T' STAT HEATER 1 HEATING T' STAT HEATER 2 PILOT LIGHT Wiring Diagram - N8600 - REMOTE 120V WIRING FOR N8600 SERIES 120V MODELS WITH ONE OR TWO HEATERS REMOTE REFRIGERATION SYSTEM FUNCTION SWITCH COLD OFF HOT COOLING T' STAT L1 G N SO
N8000 Series Drop-In Installation and Operation Manual WIRING DIAGRAM - 8100-EF, 8100-EFN ON/OFF SWITCH , #//,).' 4g34!4 . ' 16 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com #/.$%.3%2 &!.
N8000 Series Drop-In Installation and Operation Manual DROP IN LOUVER PANEL Cutout dimension 12” x 23.5” Louver part # 359-411-0003 25” 13” MISC PARTS - 8000 SERIES Description Part # Divider bar, 2” x 20.93” 265-AXE-0000 Trim gasket - sold by foot 1701273 Plastic drain 3234242 Divider bar, 12.75” x .90” 243-ALS-0032 Divider bar 21” x .90” 243-ABO-0001 Cap Tube Chart - R134A Refrigerant Model Number N8118B N8130B N8143B N8156B N8168NB N8169B N8181B Cap Tube Size/Length .036 x 72” .036 x 72” .
N8000 Series Drop-In Installation and Operation Manual replacement parts- N8100-FA 8 7 9 6 1 2 5 3 10 4 11 12 13 14 15 16 N8131-FA N8144-FA N8157-FA N8169-FA N8182-FA DESCRIPTION 2-PAN 3-PAN 4-PAN 5-PAN 6-PAN 1 UPRIGHT DIFFUSER 226-0V3-0030 226-0V3-0031 226-0V3-0032 226-0V3-0033 226-0V3-0034 2 AIR DEFLECTOR 226-A9L-0030 226-A9L-0031 226-A9L-0032 226-A9L-0033 226-A9L-0034 3 COIL 3516238 3516238 3516238 3516238 3516238 4 EXPANSION VALVE 3516273 3516273 3516273 3516273 3516273 5 BOTTOM AIR DIFFUSER
N8000 Series Drop-In Installation and Operation Manual Condensing Unit Assembly - N8200 & N8200G 1/4 h.p., 1/3 h.p. & 1/2 h.p. 3 6 4 5 1 2 1/4 HORSE POWER 1/3 HORSE POWER Key Qty Delfield Part # 1 1 3526716 2 1 000-AWP-0000 3 1 0360325 4 1 3516101 7 2 2190010 1 2183348 1 2194099 Key Qty Delfield Part # 1 1 3526710 2 1 000-AWP-0000 3 1 0360325 4 1 3516101 7 2 2190010 1 2183348 1 2194099 R-404a, Low Used on N8231, N8245, N8259,N8231G, N8245G Description condensing unit, 1/4 h.p.
N8000 Series Drop-In Installation and Operation Manual Narrow Base Condensing Unit Assembly - N8100B & N8100NB 1/5 h.p. 7 1 6 8 10 2 9 3 4 5 1/5 HORSE POWER R-134a, Low Used on N8118B, N8130B, N8143B, N8146NB, N8168NB Key 1 2 3 4 5 6 7 8 9 10 20 Qty Delfield Part # 1 3526694 1 031-264-0000 1 3516172 1 2162691 1 3516067 1 3977986 1 2183300 1 3516047 1 026-ANM-0030 1 024-ADB-0040 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Narrow Base Condensing Unit Assembly - N8100B 1/4 h.p. 3 1 2 5 8 6 7 4 1/4 HORSE POWER R-134a, Low Used on N8156B, N8169B Key Qty Delfield Part # 1 1 3526695 2 1 3977986 3 1 2183300 4 1 3516067 5 1 3516047 6 1 2194013 7 1 026-ANM-0033 8 2 028-ANK-0030 Description compressor, 1/4 h.p.
N8000 Series Drop-In Installation and Operation Manual CONDENSING UNIT ASSEMBLY 8100-EF, 8100-EFN Series Filter Dryer Compressor Relay Box Capacitor Condenser Receiving Tank Used on 8100-EF & 8100-EFN 3526716 Condensing Unit 1/4 115/60 R404A 3516101 Dryer, Filter, 1/4 ODF Low 2194231 Thermostat 2194099 On/off switch 22 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Thermostat control - N8600 9 11 10 7 5 For models N8600 Key Delfield Part # 1 265-ANQ-003D 2 265-ANS-0001 3 026-AO6-0041 4 2193979 5 2194012 6 2194190 7 3234556 8 9291234 9 3516047 10 2194185 11 2194942 6 2 8 Description FRONT,COLLAR,MTG,8600 COVER,CTRL BOX,8700 SERIES BOX,CTRL,GALV,8600 SERIES SWITCH, 3 POSITION, 30AMP THERMOSTAT, ELECTRIC LIGHT, PILOT, 125V, RED KNOB, THERMOSTAT CONTROL LABEL, “HOT/OFF/COLD” TEMPERAT
N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Infinite Control - N8700 24 For models N8700D, N8700N Key Delfield Part # - 2194110 - 2194107 1 0160009 1 0160008 2 3434703 3 3234357 4 2194007 4 2194006 5 2194335 6 3434664 7 3234557 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Thermostat control 2 1 5 3, 4 For models N8831, N8859, N8873, N8887 Key Delfield Part # Description 1 2193984 2 3234357 3 2194007 4 2194006 5 3234556 thermostat 30A for M# N8873 and N8887 plate, deflector, DFW, with drain element, heating, 208/230v, 1000/1222w element, heating, 120v, 1000w knob, thermostat control For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Standard One Year Warranty (One year parts, 90 days labor.
N8000 Series Drop-In Installation and Operation Manual Additional Four Year Protection Plan Delfield Model# Serial # (for Motor-Compressor only) Installation Date Replacement of a defective Motor-Compressor is limited to one (1) Motor-Compressor by us during the four (4) year period. Delfield shall replace the Motor-Compressor at no charge.
Covington, TN Mt. Pleasant, MI Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:_____________________ S/N: ____________________ Installation Date:_____________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com.