Delfield ™ ® N8000, N8000-R, N8100B, N8100-BR, N8100-FA, 8100-EF, N8200, N8200G, N8600, N8700-D, N8700-R, N8800 Drop Ins Service, Installation and Care Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
N8000 Series Drop-In Installation and Operation Manual Important Warning And Safety Information WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment. WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death. WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other Appliance.
N8000 Series Drop-In Installation and Operation Manual Contents Serial Number Location Receiving And Inspecting Unit..................................................... 3 The serial number on self-contained refrigerated units is on the electrical specifications tag located near the condensing unit. Specifications.......................................................................... 4-7 Installation Curved Drop-In Cutout Details...................................................
N8000 Series Drop-In Installation and Operation Manual Specifications N8100B Series Self-Contained Mechanically Cooled Pans - R134A Model L D H Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU Evap BTU/ TD/TEMP Sys Cap Ship Weight Refrig. Charge NEMA Plug 12”x20” Pans N8118B 18” (45.7cm) 26” (66cm) 21.87” (55.5cm) 17” X 25” (43.2cm x 63.5cm) 115/60/1 4.0 1/5 204 19/38º/-3º 708 100lbs (45kg) 8.0oz 5-15P 1 N8130B 30.75” (78.1cm) 26” (66cm) 21.87” (55.5cm) 29.75” x 25” (75.
N8000 Series Drop-In Installation and Operation Manual Specifications 8100-EF Series LiquiTec® Eutetic Fluid Refrigerated Cold Pans - R404A Model L D H Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU Load Evap BTU/ TD/TEMP Sys Cap Ship Weight Refrig. Charge NEMA Plug 12x20 Pans 8118-EF 18.20” (46.2cm) 26” (66cm) 23.25” (59.1cm) 17” x 25” (43.2cm x 63.5cm) 115/60/1 7.5 1/4 204 19/50º/-15° 928 169lbs (77kg) 24.0oz 5-15P 1 8132-EF 31.76” (80.7cm) 26” (66cm) 23.25” (59.
N8000 Series Drop-In Installation and Operation Manual Specifications N8000-R Series Curved Ice Cooled Cold Pans Counter Cutout Dimensions Ship Weight 12”x20” Pans Held 10.77” (27cm) see drawing on page 8 100lbs (45kg) 2 26.05” (66cm) 10.77” (27cm) see drawing on page 8 118lbs (53kg) 3 73.68” (187cm) 26.05” (66cm) 10.77” (27cm) see drawing on page 8 145lbs (65kg) 4 89.89” (228cm) 26.05” (66cm) 10.77” (27cm) see drawing on page 8 164lbs (74kg) 5 Model L D H N8044-R 40.
N8000 Series Drop-In Installation and Operation Manual Specifications N8700D Series Individually Controlled Heated Food Wells Model L D H Counter Cutout Dimensions Control Panel Cutout Dimensions Ship Weight 12”x20” Pans N8717-D 17.88” (45.4cm) 26” (66cm) 9.5” (24cm)* 16.88” X 25” (42.8cm x 63.5cm) 8.3 41lbs (19kg) 1 N8731-D 31.75” (80.6cm) 26” (66cm) 9.5” (24cm)* 120/60/1 16.6 99lbs (45kg) 2 N8745-D 45.63” (115.9cm) 26” (66cm) 14.5” x 4.62” x 7.00” (36.8cm x 11.7cm x 17.
N8000 Series Drop-In Installation and Operation Manual Curved Drop-In Cutout Details 2 pan standard curved drop-in cutout detail Models: 19.75” • N8044-R 50cm • N8144-BR • N8744-R 19.75” 50cm 172.50˚ 85˚ 2-PAN STD. RADIAL DROP-IN CUTOUT DETAIL 25.00” 64cm 25.00” 64cm 25.10” 64cm 85˚ 25.10” 64cm 95˚ 95˚ 172.50˚ 15.92” 40cm 15.92” 40cm 3 pan standard curved drop-in cutout detail Models: 19.56” • N8059-R 50cm • N8159-BR • N8759-R 17.06” 43cm 3-PAN STD. RADIAL DROP-IN CUTOUT DETAIL 25.
N8000 Series Drop-In Installation and Operation Manual Installation N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200, N8200G, N8100-FA & 8100-EF Drop In Procedure These units are intended for indoor use only. A room temperature of no more than 86°F (30°C) is recommended. Be sure the location chosen has a counter strong enough to support the total weight of the unit and contents. A fully loaded model may weigh as much as 600 pounds! Reinforce the counter as necessary to provide maximum loading.
N8000 Series Drop-In Installation and Operation Manual Installation N8700-D, N8700N, N8700-R & N8800 Series Drop In Procedure These units are intended for indoor use only. Be sure the location chosen has a counter strong enough to support the total weight of the unit and contents. A fully loaded model may weigh as much as 600 pounds! Reinforce the counter as necessary to provide maximum loading. DANGER Unit requires that the sides and bottom are not any closer than 3” (7.6cm) to any combustible material.
N8000 Series Drop-In Installation and Operation Manual Operation N8100B, N8100NB & N8100-BR N8100 Series mechanically cooled cold pans are adjusted at the factory to provide proper operation without any further adjustments. However, if it is necessary to adjust the temperature, the control is located in the machine compartment. Turn the knob clockwise as indicated on the control. Settings are from 1 thru 7 (7 being the coldest). Adjustments should be made gradually.
N8000 Series Drop-In Installation and Operation Manual Operation 8100-EF Series There is a switch on the compressor housing front to turn the 8100-EF units on and off. 8100-EF Series LiquiTec® Eutetic fluid cold pans are adjusted at the factory to provide proper operation without any further adjustments. However, if it is necessary to adjust the temperature, the control is located in the machine compartment. Turn the knob clockwise as indicated on the control to adjust it colder.
N8000 Series Drop-In Installation and Operation Manual Operation N8600 Hot/Cold Series Hot Operation N8600 Series hot and cold combination pans must be operated with water in the well for proper hot operation. Fill well with a minimum of 4” (10.2cm) of water. Place function switch in HOT position. Turn thermostat dial to highest position and allow unit to warm up. Then reset the thermostat to maintain the desired temperature. Never use anything other than plain water in the wells or tank.
N8000 Series Drop-In Installation and Operation Manual Operation N8700-D, N8700N, N8700-R & N8800 Series These units are designed to hold warm food product between 140 F to 160 F (60 C to 71 C). N8700-D, N8700N and N8700-R series individually heated hot food units may be operated “wet” (with water in the wells) or “dry”. However, “wet” operation is recommended for better performance. Wet Operation Fill the food well with a minimum of 2” (5.1cm) of water and cover with lid or empty pan.
N8000 Series Drop-In Installation and Operation Manual Maintenance Drain Maintenance - N8100-FA Series Each unit has a drain located inside the unit that removes the condensation from the evaporator coil and routes it to an external condensate evaporator pan. Each drain can become loose or disconnected during normal use. If you notice water accumulation on the inside of the unit be sure the drain tube is connected to the evaporator drain pan.
N8000 Series Drop-In Installation and Operation Manual Unit Assembly N8100-FA UPRIGHT AIR DIFFUSER WITH AIR DEFLECTOR BLACK AIRFLOW EXTRUSIONS PERFORATED PAN CLIP ADAPTER BARS COIL ASSY COVER PLEXIGLAS END CAPS Wiring Diagram N8100-FA -/$%,3 ./2$)# "2%%:% , . ' 02%3352% #/.42/, #/.$%.3).' 5.)4 $%&2/34 4)-%2 #//,).' &!.3 - <2&"!#+50<$2!7).'3<./2$)#7$ $7' Delfield ™ 16 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8100B, N8100NB & N8100-BR CONDENSER FAN S C L1 COOLING T'STAT R COMPRESSOR 115V N G Wiring Diagram 8100-EF, 8100-EFN CONDENSER FAN S C ON/OFF SWITCH L1 COOLING T'STAT R COMPRESSOR 120V N G Wiring Diagram N8200 & N8200G ON/OFF SWITCH L1 CONDENSER FAN S C R COMPRESSOR 115V N G Delfield ™ ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8630 CONDENSING UNIT COOLING THERMOSTAT M 120V-1PH-3KW HEATER 3-WAY SWITCH HEATER #1 CONTACTOR L1 HEATER #1 THERMOSTAT HEATER #1 LIMIT SWITCH N Wiring Diagram N8643 & N8656 CONDENSING UNIT COOLING THERMOSTAT M 3-WAY SWITCH HEATER #1 CONTACTOR L1 L2 HEATER #1 THERMOSTAT HEATER #1 LIMIT SWITCH N 240V-1PH-5KW HEATER Delfield ™ 18 For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8669 & N8681 L1 L2 N (2) 240V-1PH-5KW HEATERS 3-WAY SWITCH CONDENSING UNIT COOLING THERMOSTAT M HEATER #1 HEATER #1 CONTACTOR HEATER #2 HEATER #2 CONTACTOR THERMOSTAT HEATER #1 LIMIT SWITCH HEATER #2 LIMIT SWITCH Wiring Diagram N8800 208/230V LI THERMOSTAT Delfield ™ G L2 DOUBLE POLE THERMOSTAT ON MODELS N8873 & N8887 ONLY ® For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.
N8000 Series Drop-In Installation and Operation Manual Wiring Diagram N8700-D, N8700N & N8700-R PILOT LIGHT (FURNISHED) H1 1000 W - 120V OR 1000/1222 W 208-230 V HEATING ELEMENT P L1 L2 H2 LINE WIRES TO ADDITIONAL FOOD WARMERS INFINITE CONTROL WITH “OFF” POSITION AMPERES IN LINE WIRES # OF WARMERS 1 120V, 1 PHASE 8.3 2 3 4 4.8 230V, 1 PHASE 5.3 16.7 9.6 10.6 25 33.3 14.4 19.2 15.9 21.3 14.4/15.9 14.4/15.9 14.4/15.9 19.2/21.3 19.2/21.3 14.4/15.9 5 24 26.6 28.8 31.3 19.2/21.3 28.
N8000 Series Drop-In Installation and Operation Manual Drop In Louver Panel 25” 13” Louver part #359-411-0003 Cutout dimension is 11” x 22” (27.9 cm x 55.9 cm). Miscellaneous Parts 8000 SERIES Delfield Part # 265-AXE-0000 243-ALS-0032 243-AB0-0001 3234242 1701273 Description Divider bar, 2.00” x 20.93” Divider bar, 13.00” x .90” Divider bar, 21.00” x .
N8000 Series Drop-In Installation and Operation Manual Replacement Parts N8100-FA 8 7 9 6 1 2 5 3 10 4 11 12 13 14 15 16 17 N8131-FA N8144-FA N8157-FA N8169-FA N8182-FA Key Description 2-PAN 3-PAN 4-PAN 5-PAN 6-PAN 1 Upright diffuser 226-0V3-0030 226-0V3-0031 226-0V3-0032 226-0V3-0033 226-0V3-0034 2 Air deflector 226-A9L-0030 226-A9L-0031 226-A9L-0032 226-A9L-0033 226-A9L-0034 3 Coil 3510086 3510086 3510086 3510086 3510086 4 Expansion valve 3516273 3516273 3516273 3516273 3516273 5 Coil assemb
N8000 Series Drop-In Installation and Operation Manual Condensing Unit 1/4 H.P. R404a Low 8100-EF Series, 8100-EFN Series, N8131-FA, N8231, N8231G, N8245, N8245G, N8259, N8273, N8630, N8643, N8656, N8669 Key Delfield Part # 000-BN5-0030 000-BN5-003J 1 026-C58-0030 2 3516457 3 2162717 3 2162720 4 2160020 5 3526999 5 3527013 6 2194787 7 3516444 8 3516322 9 075-231-0030 10 3516454 Description Condensing Unit Assembly, 115V Condensing Unit Assembly, 220V/50Hz Shroud, Condenser Coil Blade, Fan, 7.
N8000 Series Drop-In Installation and Operation Manual Condensing Unit Assembly 1/2 H.P. R404a, Low, N8273G Key Delfield Part # 000-BN5-0033 000-BN5-003N 1 026-C58-0031 2 3516554 3 2160019 4 2162716 4 2162721 5 3516324 6 3527001 6 3527011 7 3516322 8 2194789 9 3516441 10 3516459 11 3516455 Description Condensing Unit Assembly, 115V Condensing Unit Assembly, 220V/50Hz Shroud, 1/2 HP Condenser Coil Blade, Fan, 9.
N8000 Series Drop-In Installation and Operation Manual Narrow Base Condensing Unit Assembly 1/5 H.P. R134A, Low N8118B, N8130B, N8143B, N8144-BR, N8146NB, N8159-BR, N8168NB Key Delfield Part # 1 2183300 2 3526694 2 3526718 3 3516047 4 024-ADB-0040 5 031-264-0000 6 3516172 7 2162691 7 2162692 8 026-ANM-0030 9 3516067 - 3516191 - 2194400 Description Harness, wire, power cord, 8100 Compressor, 1/5 h.p.,115v/60hz Compressor, 1/5 h.p.
N8000 Series Drop-In Installation and Operation Manual Condensing Unit Assembly 1/2 H.P. N8144-FA, N8157-FA Key Delfield Part # 000-BN5-0035 1 026-C58-0031 2 3516554 3 2160019 4 2162716 5 3516462 6 3527026 7 3516331 8 3516322 9 3516459 10 075-231-0031 11 3516455 Description Condensing Unit Assembly Shroud, 1/2 HP condenser coil Blade, fan 9.
N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Thermostat control N8600 2 1 10 9 8 7 6 5 4 3 For models N8600 Key Delfield Part # 1 2194940 1 2194942 2 026-AO6-0041 3 372-ANQ-003D 4 2193979 5 372-ANS-0001 6 2194190 7 2194202 8 3234556 9 2194185 10 3516047 Delfield ™ Description Immersion heater 120V, 1Ph 3KW Immersion heater 240V 1Ph 5KW Box, control, galv, 8600 series Front, collar, mounting, 8600 Switch, 3 position, 30Amp Cover, control box, 8700 series Ligh
N8000 Series Drop-In Installation and Operation Manual Food Well Assembly With Infinite Control N8700 For models N8700D, N8700N, N8700ND, N8700R Key Delfield Part # 1 3434703 2 2194335 3 026-103-0002 4 3434663 5 026-061-0001 6 2194007 6 2194006 7 000-BQ9-Z0000 7 000-BQ9-Z0001 - 3234557 - 2194110 - 2194107 Description Insulation, fiberglass, 9” x 48” Thermostat, non-adjustable, 480˚F Bottom cover Insulation, blanket, 24” wide Plate, deflector, DFW, with or without drain Element, heating, 208/230v, 1000
N8000 Series Drop-In Installation and Operation Manual Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
N8000 Series Drop-In Installation and Operation Manual Standard One Year Limited Warranty (One year parts, 90 days labor) The Delfield Company (“Delfield”) warrants to the Original Purchaser of the Delfield product (herein called the “Unit”) that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of one (1) year from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty car
N8000 Series Drop-In Installation and Operation Manual Additional Four Year Protection Plan Delfield Model# Serial # (for Motor-Compressor only) Installation Date In addition to the Standard One Year Warranty on the MotorCompressor contained in the above listed Delfield product (the “Unit”), The Delfield Company (“Delfield”) also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at Delfield’s option, the defective Motor-Compressor contained in the Unit (the “M
Delfield ™ ® Covington, TN Mt. Pleasant, MI Thank you for choosing Delfield! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model:_____________________ S/N: ____________________ Installation Date:_____________ For a list of Delfield’s authorized parts depots, visit our website at www.delfield.com. Delfield ™ ® 980 S. Isabella Rd., Mt. Pleasant, MI 48858, U.S.A.