Document HD Magnum Install • Installation • Operation HD Magnum Series • Repair 12.1.05 • Parts Hydraulically Driven Centrifugal Pumps Advanced Sprayer Pumps with: • Exclusive Front & Rear Wear Rings • Oversized Bearings • Two Piece Pump & Motor Design with HD Splined Coupling, Nylon Impeller, & Viton/Ceramic Seals. Delavan Pumps Inc.
HD Magnum Series Model Number Designations Pump Size Port Size - FNPT (inches) Inlet: Outlet: 1-1/4 1 1-1/2 1-1/4 2 1-1/2 M125 M150 M200 Material C S Cast iron with nylon impeller and Viton/ceramic seal (standard) Stainless steel with nylon impeller and Viton/silicon carbide seal (standard) PM21 PM37 PM45 PM58 PM58B PM70B 5-7 GPM, rear ports (for M125 only) 7-10 GPM, rear ports (for M125 & M150 only) 11-13 GPM, rear ports 13-15 GPM, rear ports 13-15 GPM, side ports 15-17 GPM, side ports -VS
Hydraulically Driven Centrifugal Pumps Size M125 Inches (mm) 1" NPT 4.00 (101.6) 3.06 (77.8) Ø7.50 (190.5) 2.19 (55.6) 13.16 (334.2) REAR PORT 8.64 (219.3) 1/2" NPT (2) 4.37 (111.0) 1-1/4 NPT 4.68 (118.9) 1/2" NPT (2) 0.56 (14.2) Slot (2) 5.25 (133.4) 4.63 (117.6) Size M150 Inches (mm) 4.71 (119.5) 1-1/4 NPT 5.41 (137.3) SIDE PORT WITH BYPASS CONTROL 13.79 (350.3) 3.50 (88.9) Ø7.50 (190.5) 2.56 (65.0) 5.41 (137.3) REAR PORT 1/2" NPT (2) 8.75 (222.1) 4.37 (111.0) 1-1/2" NPT 4.
HD Magnum Series Plumbing Recommendations Electric Pressure Regulator Valve * Electric Boom Control Valves * Control Console * Y-Line Strainer Pressure Gauge To Spray Booms Pressure Tap * Centrifugal Pump Agitation Line Y-Line Strainer Tank Agitator Anti-Vortex Fitting *Note: An electronic control console, pressure regulating valve, boom valves and pressure gauge feedback loop can be used use with the HD Magnum centrifugal pump to make a complete spray system.
Hydraulically Driven Centrifugal Pumps Typical Flow Control for Closed Center (LS) Systems Closed and Load Sensing Operation Open Center Operation 1. With the pump installed on the sprayer (as shown in the Plumbing Recommendations illustration on the facing page), fill the pump with liquid by opening the inlet ball valve. 1. With the pump installed on the sprayer (as shown in the Plumbing Recommendations illustration on the facing page), fill the pump with liquid by opening the inlet ball valve. 2.
HD Magnum Series Troubleshooting Guide Problem Causes and Remedies Pump Doesn’t Deliver Flow Suction strainer is clogged • Clean strainer Loss of prime • Make sure pump is below the liquid level • Install anti-vortex fitting in tank • Open vent line from the top-most plug on the pump volute to bleed off air • Check suction line for leaks Collapsed suction hose • Replace with wire reinforced hose • Use larger diameter hose Impeller clogged • Remove volute casing and check for foreign mat
Hydraulically Driven Centrifugal Pumps Repair Information Replacing Pump Mechanical Seal Replacing Hydraulic Motor Shaft Seal 1. Remove the four bolts on the volute using a 9/16” wrench. Fig. 1. 1. Remove motor from the pump using a 9/16” wrench. Fig. 7. 2. Remove the impeller nut using a 3/4” socket. Hold the impeller from turning by using a screwdriver in vanes of the Fig. 1 impeller. Fig. 2. 2. Using an allen wrench, unscrew the four allen bolts and remove the front flange. Fig. 8. 3.
HD Magnum Series Delavan Ag Pumps 1228 Chestnut Avenue 8 • Minneapolis, MN 55403 Document HD Magnum Install 3.15.
Hydraulically Driven Centrifugal Pumps Item # Description Part Number Qty 1 Volute Casing ........................................... 1 Size M125: 1-1/4”...................... I34-001 Size M150: 1-1/2”...................... I37-025 Size M200: 2”............................ I39-025 2 1/8” NPT Pipe Plug . ...................... 25785 4 3 Caution Label.................................. 35276 1 4 Frame O-ring Seal ........................ I34-003 1 5 3/16” Square Key.................
HD Magnum Series Returns Important Instructions for Returning Pumps All Delavan products are warranted against manufacturing defects (see warranty, below). In the event you feel you have a warranty-covered, returnable item, return the pump to your dealer, who will replace a warrantable pump for you. Delavan’s “No Hassle Warranty” puts you back in the field sooner! When you return your pump for warranty or for repair, you must always do the following: 1.
Hydraulically Driven Centrifugal Pumps Standard Warranty Delavan warrants all Roller Pumps, Turbo-90 ™ Turbine Pumps, HD Magnum™ Centrifugal Pumps, and PowerFLO™ Diaphragm Pumps for a period of one year from date of manufacture. All products sold by Delavan are warranted only to purchasers from Delavan for resale or for use in purchasers’ own business or original equipment manufacture, against defects in workmanship or materials under normal use, maintenance and service (rental use excluded).
Document HD Magnum Install 1228 Chestnut Avenue • Minneapolis, MN 55403 Toll Free: 1-866-DELAVAN (335-2826) • PH: 612-333-3189 Toll Free Fax: 1-888-726-5906 • Fax: 612-333-3231 Website: w w w. d e l a v a n a g p u m p s . c o m 3.15.