PowerFLO™ 5800/5900 Series 5830/5930: 3.0 GPM 5836/5936: 3.6 GPM Bypass Models Demand Models 5800: 4.95 (125.7) 5900: 4.84 (122.9) 5800: 4.95 (125.7) 5900: 4.84 (122.9) Inches (mm) 4.58 (116.3) 4.58 (116.3) 2.92 (74.2) 2.92 (74.2) Switch 1.87 (47.5) 2.50 (63.5) 3.21 (81.5) 7.58 (192.5) 2.50 (63.5) 3.15 (80) 4.25 (108) 5840/5940: 4.0 GPM 5850/5950: 5.0 GPM 9.08 (230.6) 7.58 (192.5) 2.50 (63.5) 3.15 (80) 4.25 (108) 5.00 (127) Bypass Models 5.00 (127) Demand Models 5800: 4.95 (125.
Pressure Sensing Demand Switch Standard Warranty Delavan warrants PowerFLO Series Pumps for a period of one year from date of manufacture. All products sold by Delavan are warranted only to purchasers from Delavan for resale or for use in purchasers’ own business or original equipment manufacture, against defects in workmanship or materials under normal use, maintenance and service (rental use excluded).
Document PF5800/5900 Install • Installation • Operation • Repair 04.15.08 • Parts PowerFLO™ 5800/5900 Series 12 Volt DC Motor-Driven Diaphragm Pumps Heat Rise Specifications 200 180 Type: 12 VDC, permanent magnet, totally enclosed, non-ventilated 160 Temperature (ϒF) Motor Leads: 14 AWG, 12” long Duty Cycle: See Heat Rise graph Temperature Limits: Motor is not equipped with thermal protection.
PowerFLO™ 5800/5900 Series Installation Recommendations Installation and Operation Precautions: Mounting: 1. The pump is equipped with a pressure sensing demand switch that controls the maximum operating pressure. Determine the optimum location for your pump. 1. The pump should be mounted in a dry place and away from any source of heat. If an enclosure is used, special instructions for cooling the motor may be necessary. Consult the Factory. 2.
12 Volt DC Motor-Driven Diaphragm Pumps Installation and Operation Troubleshooting Guide 1. Turn off water supply. Problem/Causes and Remedies 2. Cut flexible tubing in sufficient length to avoid any stress on the tubing where it connects to the pump or the fitting on any accessory. 3. Insert tubing into pump ports. If fittings are John Guest type, be sure tubing is inserted past the resistance point until it bottoms out against the port stop.
Replacement Parts PowerFlow Models 5800/5900 6 1 6 2 1 3 2 4 3 4 5 Bypass Models 5 Item Description Demand Models Part Number Qty 1 Lower Housing ............................................................................................................................................. 1 5830/5836 - 5930/5936 – Demand or Bypass......................................................... LHA5510-1E77 5840/5940 – Demand or Bypass.............................................................