Installation manual

Spa Eclipse Installation & Operations Manual
3
TubingConnection
1/4˝IDtubing
MountingFlange MountingFlange
Spa Eclipse
OzoneGenerator
ReturnFitting
Pump
Injector
CheckValve
MTM™Nozzle
LGM™Mixer
SpaController/Heater
Ozone
Flow
InletFilter
Assembly
Figure 1: Spa Eclipse Mounting & Connections
Figure 2: DEL Optimized Mixing System
andtheOzoneGenerator.ThisindicatesCheckValvefailure.
ReplacetheOzoneCheckValveandtubingimmediately.**
d.Regularlyinspecttheinletfilterfordirtbuild-up.Ifthecottonfilter
elementisclogged,removethefilterassemblyandcleanthe
filterorreplacethefilterassembly.
**WARNING: Trace amounts of nitric acid may be present in
the check valve or tubing and could be mildly corrosive. If
condensation is present shut off the ozone generator and allow
the moisture to be drawn out or dried up prior to servicing.