User Manual
Table Of Contents
- For
- High Power
- Fiber-optic Repeater System
- (MW-FBDA-PCS-xxx-50W)
- & FiberopticBase Interface Unit
- (FBIU)
- _
- The FBDA is installed near the area to be covered and is connected to the mobile antenna. A Fiberoptic transceiver converts the Downlink optical signals to RF signals and the uplink RF signals to optical signals. A duplexer in the FBDA separates the upli
- of the same antenna for receiving and transmitting. The duplexer has sharp out of band attenuation for better isolation between the receiving and
- transmitting paths and for reduction of out of band interfering signals. A high power amplifier in the downlink path produces high RF power to the antenna. A pre-amplifier is used to drive the uplink signals from the antenna to the Fiberoptic transceiver
- Limited Warranty
Dekolink WIRELESS Ltd.
16 Bazel St. Qiryat-Arieh Petah-Tikva, Israel, 49510
Tel- 972-3-9180-180 Fax-972-3- 190-9180
e-mail: marketing@dekolink.com
web www.dekolink.com
3.2 FBDA ALARM SPECIFICATIONS
RemoteFault
Indication
(Summarized
alarm)
Alarm is sent on the serial data link of the FO transmitter
to FBIU
Fault List : Power Supply Over-voltage or Under-voltage
Uplink Amplifier Over Current or Under Current
Downlink Power Amplifier Over Current or Under Current
FO Transceiver Over Current or Under Current
FO Receiver Power fall (Bad Optical Connection)
Fan Over Current or Under Current
Electrical Fault
Indication LED
Illuminated LED on Monitor Box for each Electrical Fault
Fiber Optic
Connection Fault
Indication LED
Illuminated LED on FO Transceiver when Optical
Connection is performing Correctly.
LED is OFF when FO Receiver Power falls.
FBIU alarm
output
D type 9pin male, N.C. relay contact between pin 2 and pin
4, open for active alarm + Illuminated LED on front panel.
3.3 MECHANICAL SPECIFICATIONS:
FBDA FBIU
Size 400 x 400 x 300 mm approx. 19” 1Ux250mm
Weight 25 kg. Approx. 3 kg. Approx.
Type Weatherproof Enclosure for
Wall Mounted Installation
In door, rack mount
Power Supply 110 VAC / 2A or 220VAC/1A -48V DC 1A
Molex 2.13 mm , 3 circuits
female, male pins
3.4 ENVIRONMENTAL CONDITIONS:
Operating temperature
- 30°
C to + 50
°
C
Storage temperature
- 30°
C to + 70
°
C
Weatherproof conditions Protected to IP65 (FBDA only)
FO-50W SYS Page 8 of 12