4. RF EXPOSURE WARNING
In order to satisfy the FCC RF exposure requirements, you must ensure that the
installation complies with the following:
The antenna is connected via cable that has typical 1~10 dB attenuation (depends on
the length of the cable) to the FBDA MOBILE port. In most cases, indoor or outdoor,
the antenna is omnidirectional (isotropic), or wide beam, with 0 to 3 dBi typical gain ,
VSWR: better than 1.5:1 , Impedance: 50 ohm. The antenna must be installed to
provide a minimum separation distance of 0.6 m (60 cm) from persons within the area.
For indoor applications the output power can be distributed to several antennas.
When 4 antennas (or more) are used, the indoor antenna must be installed to provide
a minimum separation distance of 0.3 m (30 cm) from persons within the area.
Fig. 6 : FBDA SYSTEM BLOCK DIAGRAM
Mobile ANT.
BTS
High pwr
ATTN.
Tx
Rx
F/O+
WDM
RF IN
RF Out
optical in/out
optical in
F/O+
WDM
optical in/out
optical Out
FBDA
RF
section
BASE SITE
FIBEROPTIC CABLE
RUN UP TO 20Km
ATTN.
(MAX. 0dBm)
F/O
F/O
RF Out
ATTN.
Rx1
Page 13 of 15 FBDA-800AB-50wDIV-INSTL1.doc